The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Technical recommendations for the use of carotid duplex ultrasound for the assessment of extracranial blood flow
Abstract
Duplex ultrasound is an evolving technology that allows the assessment of volumetric blood flow in the carotid and vertebral arteries during a range of interventions along the spectrum of health and chronic disease. Duplex ultrasound can provide high-resolution diameter and velocity information in real-time and is noninvasive with minimal risks or contraindications. However, this ultrasound approach is a specialized technique requiring intensive training and stringent control of multiple complex settings; results are highly operator-dependent, and analysis approaches are inconsistent. Importantly, therefore, methodological differences can invalidate comparisons between different imaging modalities and studies; such methodological errors have potential to discredit study findings completely. The task of this review is to provide the first comprehensive, user-friendly technical guideline for the application of duplex ultrasound in measuring extracranial blood flow in human research. An update on recent developments in the use of edge-detection software for offline analysis is highlighted, and suggestions for future directions in this field are provided. These recommendations are presented in an attempt to standardize measurements across research groups and, hence, ultimately to improve the accuracy and reproducibility of measuring extracranial blood flow both within subjects and between groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Morning Attenuation of Endothelial Function in Healthy Humans
Otto, M. E., Svatikova, A., Barretto, R. B. D. M., Santos, S., Hoffmann, M., Khandheria, B., & Somers, V. (2004) · Circulation · doi:10.1161/01.cir.0000128207.26863.c4 · Cited by 273
Effect of Coffee on Endothelial Function in Healthy Subjects: The Role of Caffeine
PAPAMICHAEL, C. M., AZNAOURIDIS, K. A., KARATZIS, E. N., KARATZI, K. N., STAMATELOPOULOS, K. S., VAMVAKOU, G., LEKAKIS, J. P., & MAVRIKAKIS, M. E. (2005) · Clinical Science · doi:10.1042/cs20040358 · Cited by 161
Cited by
Hypoxemia, oxygen content, and the regulation of cerebral blood flow
Hoiland, R. L., Bain, A. R., Rieger, M. G., Bailey, D. M., & Ainslie, P. N. (2016) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00270.2015 · Cited by 255
Self-citation
Metadata
- Authors
- Thomas, K. N., Lewis, N. C. S., Hill, B. G., & Ainslie, P. N.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2015-10
- Volume
- 309
- Issue
- 7
- Pages
- R707-R720
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2233146458
- Cited by
- 167
- References
- 2
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.