The DOI matches its Crossref record.
Cardiovascular responses to elevation of intra-abdominal hydrostatic pressure
Abstract
Intra-abdominal fluid volume and hydrostatic pressure were elevated by positive pressure infusion of Tyrode solution into the peritoneal cavity of anesthetized dogs. The compliance of the peritoneal cavity fell from 10.8 to 0.56 ml X mmHg-1 X kg-1 of body wt as intra-abdominal pressure increased from 0 to 40 mmHg. Intrathoracic pressure also increased as elevated peritoneal pressure caused diaphragmatic bulging. Cardiac output and stroke volume were reduced by 36% after an intra-abdominal pressure rise of 40 mmHg; in contrast, heart rate did not change. Flow in the celiac, superior mesenteric, and renal arteries was reduced by 42, 61, and 70%, respectively. Pressure in the femoral vein increased to 46 mmHg, while flow in the femoral artery decreased by 65%. Whole-body O2 consuxmption, pH, and arterial PO2 decreased as intra-abdominal pressure rose. The peritoneal cavity, with its high initial compliance, affords the body an ideal location for the temporary accumulation of small to moderate volumes of fluid during episodes of increased vascular pressure or permeability. The marked alterations in the hemodynamic properties of the cardiovascular system are indicative of the physiological changes that occur when intra-abdominal fluid accumulation becomes excessive and peritoneal pressure rises to high levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prospective characterization and selective management of the abdominal compartment syndrome
Meldrum, D. R., Moore, F. A., Moore, E. E., Franciose, R. J., Sauaia, A., & Burch, J. M. (1997) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)00201-8 · Cited by 443
Elevated Intra-Abdominal Pressure in Acute Decompensated Heart Failure
Mullens, W., Abrahams, Z., Skouri, H. N., Francis, G. S., Taylor, D. O., Starling, R. C., Paganini, E., & Tang, W. H. W. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.043 · Cited by 427
INTRA-ABDOMINAL HYPERTENSION AND THE ABDOMINAL COMPARTMENT SYNDROME
Ivatury, R. R., Diebel, L., Porter, J. M., & Simon, R. J. (1997) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70584-3 · Cited by 341
Acute mesenteric ischemia: Pathophysiology, diagnosis, and treatment
Benjamin, E., & Oropello, J. M. (1993) · Disease-a-Month · doi:10.1016/0011-5029(93)90023-v · Cited by 150
Metadata
- Authors
- Barnes, G. E., Laine, G. A., Giam, P. Y., Smith, E. E., & Granger, H. J.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1985-02-01
- Volume
- 248
- Issue
- 2
- Pages
- R208-R213
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W1957291864
- Cited by
- 220
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiovascular responses to elevation of intra-abdominal hydrostatic pressure. https://app.cochat.ai/papers/10.1152/ajpregu.1985.248.2.r208
- The paper
- Barnes, G. E., Laine, G. A., Giam, P. Y., Smith, E. E., & Granger, H. J. (1985). Cardiovascular responses to elevation of intra-abdominal hydrostatic pressure. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1985.248.2.r208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.