Total body electrical conductivity measurements: effects of body composition and geometry
The DOI matches its Crossref record.
Abstract
This study used an animal model to analyze the effect of body geometry and chemical composition on the calibration of a total body electrical conductivity (TOBEC) instrument developed to measure the body composition of human infants. The TOBEC signal (adjusted for length) of infant miniature pigs from 10 to 33 days of age correlated highly with their chemically analyzed fat-free mass (FFM; r = 0.998) and total body water contents (TBW; r = 0.998); 95% prediction intervals (approximately +/- 2 SEE) for individual measurements were +/- 0.16 kg FFM and +/- 0.12 liter water. These values were significantly improved (+/- 0.08 kg and +/- 0.06 liter, respectively) by accounting for individual variability in weight/length2. The effect of variations in the composition of FFM on the TOBEC measurements was evaluated by comparing the response of the infant piglets with that of adult rabbits of similar size. The differences in composition, primarily TBW and Na content, were insufficient to alter the electrical properties of FFM appreciably. Thus the TOBEC used under the conditions defined in this study accurately predicted the FFM and TBW content of infant miniature pigs. The calibration derived from the piglets will be applicable to the interpretation of the TOBEC measurements of human infants provided their FFM is of comparable shape to that of the piglets. Differences in composition are likely to be of consequence only if the proportion of fat within the FFM and the FFM density are widely divergent. This, however, does not appear to be the case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mei, Z., Grummer-Strawn, L. M., Pietrobelli, A., Goulding, A., Goran, M. I., & Dietz, W. H. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.6.978 · Cited by 987
Catalano, P., & Ehrenberg, H. (2006) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2006.00989.x · Cited by 831
Lipshultz, S. E., Adams, M. J., Colan, S. D., Constine, L. S., Herman, E. H., Hsu, D. T., Hudson, M. M., Kremer, L. C., Landy, D. C., Miller, T. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182a88099 · Cited by 612
Increased fetal adiposity: a very sensitive marker of abnormal in utero development
Catalano, P. M., Thomas, A., Huston-Presley, L., & Amini, S. B. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(03)00828-7 · Cited by 519
Increased neonatal fat mass, not lean body mass, is associated with maternal obesity
Sewell, M. F., Huston-Presley, L., Super, D. M., & Catalano, P. (2006) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2006.06.014 · Cited by 429
Metadata
- Authors
- Fiorotto, M. L., Cochran, W. J., Funk, R. C., Sheng, H. P., & Klish, W. J.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1987-04-01
- Volume
- 252
- Issue
- 4
- Pages
- R794-R800
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2266797848
- Cited by
- 79
- References
- 0
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Total body electrical conductivity measurements: effects of body composition and geometry. https://app.cochat.ai/papers/10.1152/ajpregu.1987.252.4.r794
- The paper
- Fiorotto, M. L., Cochran, W. J., Funk, R. C., Sheng, H. P., & Klish, W. J. (1987). Total body electrical conductivity measurements: effects of body composition and geometry. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1987.252.4.r794
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.