Size selectivity of blood-brain barrier permeability at various times after osmotic opening
The DOI matches its Crossref record.
Abstract
Recent experiments have shown that after osmotic opening the blood-brain barrier recloses more rapidly to larger than to smaller molecules. Quantitative theoretical analysis of blood-brain barrier permeability to different-sized molecules at different times after osmotic opening supports the concept of pore creation as a result of opening of tight junctions between endothelial cells. Experiments also suggest significant bulk water flow from capillaries into brain within 10 min after opening at an average rate of approximately 1.6 X 10(-4) cm3 X s-1 X g brain-1. A mathematical model of blood-brain barrier permeability based on the creation of pores, together with bulk fluid flow, is presented for both cylindrical pores and rectangular slits. Experimental data are compatible with pore radii of approximately 200 A or slit widths of approximately 220 A. Pore densities of approximately 1 pore per 200 microns 2 of membrane surface are calculated at 6 min after barrier opening, reducing slightly as the barrier recloses. Calculated bulk flow is reduced by an order of magnitude within 35 min of barrier opening and is a major factor in altered blood-brain barrier permeability. Size dependence of blood-brain barrier permeability following osmotic opening is shown to be incompatible with enhanced vesicular transport.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical resistance across the blood-brain barrier in anaesthetized rats: a developmental study.
Butt, A. M., Jones, H. C., & Abbott, N. J. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018243 · Cited by 775
Nonviral Vectors in the New Millennium: Delivery Barriers in Gene Transfer
Nishikawa, M., & Huang, L. (2001) · Human Gene Therapy · doi:10.1089/104303401750195836 · Cited by 574
Osmotic Opening of the Blood–Brain Barrier: Principles, Mechanism, and Therapeutic Applications
Rapoport, S. I. (2000) · Cellular and Molecular Neurobiology · doi:10.1023/a:1007049806660 · Cited by 428
“, 1980), fin was calculated to equal 16 3 1025 cm3 ? s21 ? g brain21 in the 10 min following infusion and 0 at 35 and 55 min (Robinson and Rapoport, 1987; Ziylan et al., 1984).”
BackgroundMethodInfluentialEvolving Drug Delivery Strategies to Overcome the Blood Brain Barrier
S. Hersh, D., S. Wadajkar, A., B. Roberts, N., G. Perez, J., P. Connolly, N., Frenkel, V., A. Winkles, J., F. Woodworth, G., & J. Kim, A. (2016) · Current Pharmaceutical Design · doi:10.2174/1381612822666151221150733 · Cited by 387
“Following the intra-carotid infusion of mannitol, BBB permeability persists for 15 minutes to 4 hours depending on the size of the molecule being transported, with the barrier reclosing sooner to larger molecules [18, 19].”
Chen, H., & Konofagou, E. E. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.71 · Cited by 262
Metadata
- Authors
- Robinson, P. J., & Rapoport, S. I.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1987-09-01
- Volume
- 253
- Issue
- 3
- Pages
- R459-R466
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2343974526
- Cited by
- 59
- References
- 0
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Size selectivity of blood-brain barrier permeability at various times after osmotic opening. https://app.cochat.ai/papers/10.1152/ajpregu.1987.253.3.r459
- The paper
- Robinson, P. J., & Rapoport, S. I. (1987). Size selectivity of blood-brain barrier permeability at various times after osmotic opening. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1987.253.3.r459
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.