The DOI matches its Crossref record.
Heart rate control in normal and aborted-SIDS infants
Abstract
Approximate entropy (ApEn), a mathematical formula quantifying regularity in data, was applied to heart rate data from normal and aborted-sudden infant death syndrome (SIDS) infants. We distinguished quiet from rapid-eye-movement (REM) sleep via the following three criteria, refining the notion of REM as more "variable": 1) REM sleep has greater overall variability (0.0374 +/- 0.0138 vs. 0.0205 +/- 0.0090 s, P < 0.005); 2) REM sleep is less stationary (StatAv = 0.742 +/- 0.110) than quiet sleep (StatAv = 0.599 +/- 0.159, P < 0.03); 3) after normalization to overall variability, REM sleep is more regular (ApEnsub = 1.224 +/- 0.092) than quiet sleep (ApEnsub = 1.448 +/- 0.071, P < 0.0001). Fifty percent of aborted-SIDS infants showed greater ApEn instability across quiet sleep than any normal infant exhibited, suggesting that autonomic regulation of heart rate occasionally becomes abnormal in a high-risk subject. There was an association between low ApEn values and aborted-SIDS events; 5 of 14 aborted-SIDS infants had at least one quiet sleep epoch with an ApEn value below the minimum of 45 normal-infant ApEn values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Physiological time-series analysis: what does regularity quantify?
Pincus, S. M., & Goldberger, A. L. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.266.4.h1643 · Cited by 1,315
Self-citationApproximate entropy (ApEn) as a complexity measure
Pincus, S. (1995) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166092 · Cited by 1,213
Self-citationApproximate Entropy-Based Epileptic EEG Detection Using Artificial Neural Networks
Srinivasan, V., Eswaran, C., & Sriraam, N. (2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.884369 · Cited by 591
Changing complexity in human behavior and physiology through aging and disease
Vaillancourt, D. E., & Newell, K. M. (2002) · Neurobiology of Aging · doi:10.1016/s0197-4580(01)00247-0 · Cited by 551
Metadata
- Authors
- Pincus, S. M., Cummins, T. R., & Haddad, G. G.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1993-03-01
- Volume
- 264
- Issue
- 3
- Pages
- R638-R646
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W1856016326
- Cited by
- 208
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart rate control in normal and aborted-SIDS infants. https://app.cochat.ai/papers/10.1152/ajpregu.1993.264.3.r638
- The paper
- Pincus, S. M., Cummins, T. R., & Haddad, G. G. (1993). Heart rate control in normal and aborted-SIDS infants. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1993.264.3.r638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.