CoChat

Gastric volume detection after selective vagotomies in rats

Phillips, Robert J., Powley, Terry L. · 1998 · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Cited by 85

The DOI matches its Crossref record.

Abstract

Rats receiving intragastric infusions of 2.5, 5.0, 7.5, or 10.0 ml of normal saline while their pylori are reversibly occluded suppress meal size to the smallest infusion and display a dose-dependent reduction across volumes [Phillips, R. J., and T. L. Powley. Am. J. Physiol. 271 ( Regulatory Integrative Comp. Physiol.40): R766–R779, 1996]. To evaluate the contributions of the vagus to this detection of gastric volume, groups prepared with different selective vagotomies and equipped with pyloric cuffs and gastric catheters were tested. Liquid diet consumption during a 30-min feeding bout was measured after infusions of 5.0 and 10.0 ml of normal saline on cuff-open and cuff-closed trials. Consistent with earlier observations, sham animals with cuffs closed exhibited volume-dependent suppression of food intake to the infusions, and completely vagotomized animals did not inhibit feeding in response to the loads. In cuff-closed trials, the suppression function slopes of the selective vagotomy groups were intermediate to those of the shams and the completely vagotomized animals. Furthermore, for the different groups, the extent of suppression after vagotomy was proportional to the density of the afferent innervation respective branches supplied to the stomach. Specifically, the group with the gastric branches spared (nonsignificantly attenuated in comparison to shams) and the group with only the hepatic branch spared (significantly attenuated with respect to shams) both still exhibited significant dose-dependent suppression slopes (compared with completes), whereas the group with only celiac branches spared was not significantly different from completely vagotomized animals. In sum, the vagus nerve mediates the detection of the gastric volumes tested, and the different branches of the vagus make distinctive contributions to this afferent feedback.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpregu.1998.274.6.r1626

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 85

Metadata

Authors
Phillips, R. J., & Powley, T. L.
Venue
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Published
1998-06-01
Volume
274
Issue
6
Pages
R1626-R1638
ISSN
  • 0363-6119 (ISSN-L)
  • 1522-1490
OpenAlex
W2184606226
Cited by
85
References
0
FWCI
1.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gastric volume detection after selective vagotomies in rats. https://app.cochat.ai/papers/10.1152/ajpregu.1998.274.6.r1626
The paper
Phillips, R. J., & Powley, T. L. (1998). Gastric volume detection after selective vagotomies in rats. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1998.274.6.r1626

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.