Evaluation of different levels of hydration using a new physiological strain index
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A physiological strain index (PSI), based on rectal temperature (T re) and heart rate (HR), was recently suggested for evaluating heat stress. The purpose of this study was to evaluate the PSI for different combinations of hydration level and exercise intensity. This index was applied to two databases. The first database was obtained from eight endurance-trained men dehydrated to four different levels (1.1, 2.3, 3.4, and 4.2% of body wt) during 120 min of cycling at a power output of 62–67% maximum O 2 consumption (V˙o 2 max) in the heat [33°C and 50% relative humidity (RH)]. The second database was obtained from nine men performing exercise in the heat (30°C and 50% RH) for 50 min. These subjects completed a matrix of nine trials of exercise on a treadmill at three exercise intensities (25, 45, and 65%V˙o 2 max) and three hydration levels (euhydration and hypohydration at 3 and 5% of body wt). T re, HR, esophageal temperature (T es), and local sweating rate were measured. PSI (obtained from either T re or T es) significantly ( P < 0.05) differentiated among all exposures in both databases categorized by exercise intensity and hydration level, and we assessed the strain on a scale ranging from 0 to 10. Therefore, PSI applicability was extended for heat strain associated with hypohydration and continues to provide the potential to be universally accepted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of graded dehydration on hyperthermia and cardiovascular drift during exercise
Montain, S. J., & Coyle, E. F. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.73.4.1340 · Cited by 769 · cited 7×
“The PSI was applied to two databases (16, 17).”
BackgroundMethodSelf-citation
Cited by
A non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129
Chan, A. P. C., Yi, W., Wong, D. P., Yam, M. C. H., & Chan, D. W. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.07.006 · Cited by 91
“[34] introduced a Physiological Strain Index (PSI), which is based on heart rate and core temperature records in humans, to describe heat strain in quantitative terms during continuous exercise [35].”
Background
Metadata
- Authors
- Moran, D. S., Montain, S. J., & Pandolf, K. B.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1998-09-01
- Volume
- 275
- Issue
- 3
- Pages
- R854-R860
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2136581190
- Cited by
- 90
- References
- 1
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of different levels of hydration using a new physiological strain index. https://app.cochat.ai/papers/10.1152/ajpregu.1998.275.3.r854
- The paper
- Moran, D. S., Montain, S. J., & Pandolf, K. B. (1998). Evaluation of different levels of hydration using a new physiological strain index. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1998.275.3.r854
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.