The DOI matches its Crossref record.
Chronically Implanted Polarographic Electrodes
Abstract
Insulated metal polarographic cathodes were permanently implanted in the brains of cats, allowing continuous recording of oxygen availability. A study was made of the current flow as related to applied potential, nature of the cathode and alterations in brain physiology. Mean oxygen availability increases about 2-fold on breathing oxygen, 3-fold on breathing air containing 14% carbon dioxide and decreases with hypoxic gas mixtures. The oxygen availability to the brain is only slightly altered by a wide variety of pharmacological agents, including anesthetics and pressor agents, but appears to parallel changes in carbon dioxide tension and to be increased by ethyl and vinyl ether. A day or two after implantation of a cathode, waves having a frequency of 6–12/min. and an amplitude of up to ±30% of the mean current are obtained. Their frequency and amplitude are temperature-dependent and can be altered by various chemical agents. The waves are asynchronous from cathodes spaced farther apart than a few millimeters. All the observations to date are consistent with the concept that these waves represent fluctuations in the amount of oxygen available at the cathode due to rhythmic variations in blood flow through the finer cerebral vessels. Submitted on February 19, 1958
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spontaneous fluctuations in brain activity observed with functional magnetic resonance imaging
Fox, M. D., & Raichle, M. E. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2201 · Cited by 6,700
Survival of Mammals Breathing Organic Liquids Equilibrated with Oxygen at Atmospheric Pressure
Clark, L. C., & Gollan, F. (1966) · Science · doi:10.1126/science.152.3730.1755 · Cited by 794
Self-citationAlzheimer Disease: Evaluation of a Functional MR Imaging Index as a Marker
Li, S.-J., Li, Z., Wu, G., Zhang, M.-J., Franczak, M., & Antuono, P. G. (2002) · Radiology · doi:10.1148/radiol.2251011301 · Cited by 292
Metadata
- Authors
- Clark, L. C., Misrahy, G., & Fox, R. P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1958-07
- Volume
- 13
- Issue
- 1
- Pages
- 85-91
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2272629027
- Cited by
- 165
- References
- 0
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronically Implanted Polarographic Electrodes. https://app.cochat.ai/papers/10.1152/jappl.1958.13.1.85
- The paper
- Clark, L. C., Misrahy, G., & Fox, R. P. (1958). Chronically Implanted Polarographic Electrodes. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1958.13.1.85
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.