The DOI matches its Crossref record.
Pulmonary capillary blood volume, flow and diffusing capacity during exercise
Abstract
Pulmonary capillary blood flow (Qc) and apparent CO diffusing capacity (Dl) were calculated from the rates of disappearance of small alveolar concentrations of inspired acetylene and carbon monoxide during breath holding. Such measurements were performed simultaneously in four normal subjects at rest, during exercise and while performing Valsalva or Mueller maneuvers; they were also made at more than one alveolar oxygen tension so that true membrane diffusing capacity (Dm) and pulmonary capillary blood volume (Vc) could be calculated by the method of Roughton and Forster. Dl, Dm and Vc were closely correlated with Qc (r = 0.92, 0.71 and 0.92, respectively), indicating that both volume and effective surface of the pulmonary capillary bed changed along with corresponding directional changes in blood flow. During transients after starting or after stopping exercise, changes in Dl lagged slightly behind the associated changes in Qc; both parameters tended to reach steady values, however, after about 1 minute of steady exercise. The average time spent by red cells in the pulmonary capillaries at rest was estimated to be 0.79 second, falling to about 0.5 second at levels of exercise at which volume flow through the capillary bed was approximately tripled. Submitted on September 18, 1959
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pulmonary blood volume and pulmonary capillary blood volume in valvular heart disease.
GAZIOGLU, K., & YU, P. N. (1967) · Circulation · doi:10.1161/01.cir.35.4.701 · Cited by 23
Metadata
- Authors
- Johnson, R. L., Spicer, W. S., Bishop, J. M., & Forster, R. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1960-09-01
- Volume
- 15
- Issue
- 5
- Pages
- 893-902
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2237821013
- Cited by
- 242
- References
- 0
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.