CoChat

Effect of inflation of the lung on different parts of pulmonary vascular bed

Howell, J. B. L., Permutt, Solbert, Proctor, D. F., Riley, R. L. · 1961 · Journal of Applied Physiology
Cited by 324

The DOI matches its Crossref record.

Abstract

In excised lungs of dogs, the static pressure-volume characteristics of the vascular bed were determined with the vessels filled with dextran and again after replacement of the dextran with kerosene. Whereas the dextran was distributed throughout the entire vascular bed, the kerosene was distributed only in relatively large vessels due to interfacial tension. Volume-pressure curves obtained with kerosene were markedly different from those obtained with dextran. Utilizing both types of volume-pressure curves, it was possible to separate the vascular bed of the lung into two compartments that responded oppositely to inflation of the lung when vascular pressure was held constant: one compartment, consisting of relatively large vessels, always increased in volume; the other compartment, consisting of smaller vessels, always decreased in volume. Submitted on June 9, 1960

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1961.16.1.71

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Howell, J. B. L., Permutt, S., Proctor, D. F., & Riley, R. L.
Venue
Journal of Applied Physiology
Published
1961-01-01
Volume
16
Issue
1
Pages
71-76
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2186711396
Cited by
324
References
0
FWCI
11.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.