The DOI matches its Crossref record.
Hemodynamics of collapsible vessels with tone: the vascular waterfall
Abstract
A theoretical analysis is presented of pressure-flow relationships in arterioles based on the assumption that the presence of active tension produced by smooth muscle contraction causes a critical closing pressure which is itself a function of the magnitude of the active tension. This analysis differs from those previously carried out in that it uses the pressure-flow relationships of a waterfall rather than those described by Poiseuille's law to characterize the flow between arterioles and capillaries in the presence of active tension. It is suggested that, under some conditions, the driving pressure for the flow through arterioles is not the difference between the inflow pressure and outflow pressure of the arterioles, but rather the difference between the inflow pressure and the critical closing pressure. This seemingly slight modification causes marked differences in the interpretation of pressure-flow relationships and vascular resistance in the presence of active tone. Submitted on December 10, 1962
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cannon, R. O., Rosing, D. R., Maron, B. J., Leon, M. B., Bonow, R. O., Watson, R. M., & Epstein, S. E. (1985) · Circulation · doi:10.1161/01.cir.71.2.234 · Cited by 477
Upper Airway Collapsibility in Snorers and in Patients with Obstructive Hypopnea and Apnea
Gleadhill, I. C., Schwartz, A. R., Schubert, N., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.6.1300 · Cited by 453
Self-citationPathophysiology of Upper Airway Obstruction: a Developmental Perspective
Arens, R., & Marcus, C. L. (2004) · Sleep · doi:10.1093/sleep/27.5.997 · Cited by 432
Diastolic coronary artery pressure-flow relations in the dog.
Bellamy, R. F. (1978) · Circulation Research · doi:10.1161/01.res.43.1.92 · Cited by 300
The pathogenesis of obstructive sleep apnea.
(2015) · PubMed Central · doi:10.3978/j.issn.2072-1439.2015.07.28 · Cited by 90
Metadata
- Authors
- Permutt, S., & Riley, R. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1963-09-01
- Volume
- 18
- Issue
- 5
- Pages
- 924-932
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1802302318
- Cited by
- 545
- References
- 0
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamics of collapsible vessels with tone: the vascular waterfall. https://app.cochat.ai/papers/10.1152/jappl.1963.18.5.924
- The paper
- Permutt, S., & Riley, R. L. (1963). Hemodynamics of collapsible vessels with tone: the vascular waterfall. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1963.18.5.924
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.