The DOI matches its Crossref record.
Resistance of central and peripheral airways measured by a retrograde catheter
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Beydon, N., Davis, S. D., Lombardi, E., Allen, J. L., Arets, H. G. M., Aurora, P., Bisgaard, H., Davis, G. M., Ducharme, F. M., Eigen, H., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-642st · Cited by 1,250
Lynch, D. A., Austin, J. H. M., Hogg, J. C., Grenier, P. A., Kauczor, H.-U., Bankier, A. A., Barr, R. G., Colby, T. V., Galvin, J. R., Gevenois, P. A., et al. (2015) · Radiology · doi:10.1148/radiol.2015141579 · Cited by 658
On the imperfect elasticity of lung tissue
Fredberg, J. J., & Stamenovic, D. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.6.2408 · Cited by 494
Acute Bronchial Asthma: Relations between Clinical and Physiologic Manifestations
McFadden, E. R., Kiser, R., & DeGroot, W. J. (1973) · New England Journal of Medicine · doi:10.1056/nejm197302012880501 · Cited by 485
Hogg, J. C., Williams, J., Richardson, J. B., Macklem, P. T., & Thurlbeck, W. M. (1970) · New England Journal of Medicine · doi:10.1056/nejm197006042822302 · Cited by 283
Self-citation
Metadata
- Authors
- Macklem, P. T., & Mead, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1967-03-01
- Volume
- 22
- Issue
- 3
- Pages
- 395-401
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1765749507
- Cited by
- 741
- References
- 0
- FWCI
- 29.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resistance of central and peripheral airways measured by a retrograde catheter. https://app.cochat.ai/papers/10.1152/jappl.1967.22.3.395
- The paper
- Macklem, P. T., & Mead, J. (1967). Resistance of central and peripheral airways measured by a retrograde catheter. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1967.22.3.395
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.