Frequency and displacement amplitude relations for normal hand tremor
The DOI matches its Crossref record.
Abstract
Spectral analysis of hand tremor records obtained from normal subjects during continuous extension of the hand for 15–45 min revealed that the root-mean-square (rms) displacement amplitude of the tremor increased from control levels of about 30 mum to levels on the order of 100–1,000 times control. Associated with this increase in the displacement was a systematic decrease in the hand tremor frequency from control values of 8–9 Hz to values of 4–6 Hz. Spectral analysis of demodulated extensor EMG records indicated a consistent relation between EMG modulation amplitude at the tremor frequency and the tremor displacement amplitude for tremor records with rms displacement above about 100 mum. No consistent relation was found between these two variables for tremor records with displacements below 100 mum. Consideration of both mechanical and neural reflex effects indicated that a viscoelastic-mass mechanism primarily determined the small-amplitude (less than 100 mum) tremors, while the large displacement tremors may have involved both mechanical and neural feed back factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Winters, J. M., & Stark, L. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325498 · Cited by 526
Lee, R. G., & Stein, R. B. (1981) · Annals of Neurology · doi:10.1002/ana.410100606 · Cited by 205
A software for recording and analysis of human tremor
Lauk, M., Timmer, J., Lücking, C. H., Honerkamp, J., & Deuschl, G. (1999) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(99)00012-7 · Cited by 56
Passive mechanical properties of the wrist and physiological tremor.
Lakie, M., Walsh, E. G., & Wright, G. W. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.6.669 · Cited by 47
THE EFFECT OF MECHANICAL IMPEDANCE ON ABNORMAL INTENTION TREMOR
Adelstein, B. D., & Rosen, M. J. (1981) · Bioengineering · doi:10.1016/b978-0-08-027207-8.50047-3 · Cited by 28
Metadata
- Authors
- Stiles, R. N.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1976-01-01
- Volume
- 40
- Issue
- 1
- Pages
- 44-54
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1932172401
- Cited by
- 103
- References
- 0
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency and displacement amplitude relations for normal hand tremor. https://app.cochat.ai/papers/10.1152/jappl.1976.40.1.44
- The paper
- Stiles, R. N. (1976). Frequency and displacement amplitude relations for normal hand tremor. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1976.40.1.44
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.