Reflex and mechanical circulatory effects of graded Valsalva maneuvers in normal man
The DOI matches its Crossref record.
Abstract
In 17 normal subjects we studied the changes evoked by five levels of expiratory pressure (EP) ranging from 2.5 to 30 mmHg in a number of circulatory variables during the last 10 s of a 30-s Valsalva maneuver. Variables studied included mean arterial (MAP) and pulse (PP) pressures; right atrial (RAP) and peripheral vein (PVP) pressures; cardiac output (CO); total peripheral resistance (TPR) and heart rate (HR). EP-circulatory response curves were obtained in each subject a) before autonomic block; b) after cardiac effector block (atropine + propranolol); c) after “total” autonomic block (atropine + propranolol; guanethidine + phentolamine). Mechanical effects were determined from results during “total” autonomic block. They included EP-related rises in RAP and PVP each to about 0.7 mmHg/mmHg applied EP, and falls in CO, MAP, and PP to levels of approximately 50%, 70%, and 80% of resting respectively at EP 30 mmHg, but no changes in TPR and HR. Reflex effects included EP-related rises in HR and in TPR and in MAP, to levels of 160%, 160%, and 115% of resting respectively at EP 30 mmHg. The afferent input profile is probably complex, and the role of the different receptor groups may vary at the different levels of EP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sztajzel, J. (2004) · Swiss Medical Weekly · doi:10.4414/smw.2004.10321 · Cited by 779
How to measure baroreflex sensitivity: from the cardiovascular laboratory to daily life
Parati, G., Di Rienzo, M., & Mancia, G. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018010-00003 · Cited by 516
Arterial Baroreflexes in Humans
Mancia, G., & Mark, A. L. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020320 · Cited by 292
Interactions Between Respiration and Circulation
De Burgh Daly, M. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030216 · Cited by 232
The peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 232
“beats) blood pressure rise with bradycardia [24-27] as intrathoracic pressure is increased, of amplitude proportional to the increase in intrathoracic pressure (the four reasons are described above).”
BackgroundA human cardiopulmonary system model applied to the analysis of the Valsalva maneuver
Lu, K., Clark, J. W., Ghorbel, F. H., Ware, D. L., & Bidani, A. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.281.6.h2661 · Cited by 218
“PSA p (VSA) 5 Kp1 3 e tp 3 ~VSA 2 VSA,0! 1 Kp2 3 ~VSA 2 VSA,0! 2 (14)”
The Valsalva manoeuvre: physiology and clinical examples
Pstras, L., Thomaseth, K., Waniewski, J., Balzani, I., & Bellavere, F. (2016) · Acta Physiologica · doi:10.1111/apha.12639 · Cited by 188
“With the total autonomic blockade, the phases I and III remain unchanged proving that the arterial pressure changes in these phases are of purely mechanical origin (Korner et al. 1976).”
BackgroundInfluentialDisorders of the autonomic nervous system: Part 2. investigation and treatment
McLeod, J. G., & Tuck, R. R. (1987) · Annals of Neurology · doi:10.1002/ana.410210602 · Cited by 162
Blood pressure recovery from Valsalva maneuver in patients with autonomic failure
Vogel, E. R., Sandroni, P., & Low, P. A. (2005) · Neurology · doi:10.1212/01.wnl.0000184504.13173.ef · Cited by 160
Assessment of sympathetic index from the Valsalva maneuver
Novak, P. (2011) · Neurology · doi:10.1212/wnl.0b013e31821e5563 · Cited by 88
Sandroni, P., Novak, V., Opfer-Gehrking, T. L., Huck, C. A., & Low, P. A. (2000) · Clinical Autonomic Research · doi:10.1007/bf02291382 · Cited by 38
“Phase II_E is due to reduction in preload, partially blunted by vagal withdrawal [3,4].”
Background
Metadata
- Authors
- Korner, P. I., Tonkin, A. M., & Uther, J. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1976-03-01
- Volume
- 40
- Issue
- 3
- Pages
- 434-440
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2102282914
- Cited by
- 188
- References
- 0
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.