Measurement of VO2, VCO2, and evaporative water loss with a flow-through mask
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Equations for the calculation of VO2, VCO2, and evaporative water loss were derived for use of a paramagnetic gas analyzer with a flow-through respirometry system and an open or closed mask. The magnitude of errors involved in the determination of VO2 with no CO2 absorbent are small (+/-3%) but may be greater if no H2O absorbent is used, unless an appropriate correctionis made for evaporative water loss. Data collected for hummingbirds (Selasphorus sasin) and monitor lizards (Varanus gouldii) indicate the validity ofthe technics described for the measurement of RQ and evaporative water lossand demonstrate the use of paramagnetic gas analyzers in monitoring respiratory patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brody, S., & Lardy, H. A. (1946) · The Journal of Physical Chemistry · doi:10.1021/j150446a008 · Cited by 3,459
Depocas, F., & Hart, J. S. (1957) · Journal of Applied Physiology · doi:10.1152/jappl.1957.10.3.388 · Cited by 553
Oxygen Consumption of Torpid, Resting, Active, and Flying Hummingbirds
Lasiewski, R. C. (1963) · Physiological Zoology · doi:10.1086/physzool.36.2.30155436 · Cited by 330
Running in cheetahs, gazelles, and goats: energy cost and limb configuration
Taylor, C. A., Shkolnik, A., Dmi’el, R., Baharav, D., & Borut, A. (1974) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1974.227.4.848 · Cited by 138
The metabolic responses of the common iguana, Iguana iguana, to walking and diving
Moberly, W. R. (1968) · Comparative Biochemistry and Physiology · doi:10.1016/0010-406x(68)90750-0 · Cited by 122
Body Temperatures, Heart and Breathing Rate, and Evaporative Water Loss in Hummingbirds
Lasiewski, R. C. (1964) · Physiological Zoology · doi:10.1086/physzool.37.2.30152332 · Cited by 107
Bennett, A. F. (1973) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(73)90120-5 · Cited by 90
Cited by
The theoretical bases of indirect calorimetry: A review
Ferrannini, E. (1988) · Metabolism · doi:10.1016/0026-0495(88)90110-2 · Cited by 1,580
Martin, L. B., Scheuerlein, A., & Wikelski, M. (2003) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2002.2185 · Cited by 513
Regulation of Body Temperature
Whittow, G. C. (1986) · Avian Physiology · doi:10.1007/978-1-4612-4862-0_9 · Cited by 357
The Cost of Living: Field Metabolic Rates of Small Mammals
Speakman, J. R. (1999) · Advances in Ecological Research · doi:10.1016/s0065-2504(08)60019-7 · Cited by 320
Buck, C. L., & Barnes, B. M. (2000) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2000.279.1.r255 · Cited by 302
Metadata
- Authors
- Withers, P. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1977-01-01
- Volume
- 42
- Issue
- 1
- Pages
- 120-123
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2311971423
- Cited by
- 866
- References
- 7
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.