Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 291

The DOI matches its Crossref record.

Effects of respiratory apparatus on breathing pattern

Askanazi, J., Silverberg, P. A., Foster, R. J., Hyman, A. I., Milic-Emili, J., Kinney, J. M.·1980·Journal of Applied Physiology

Abstract

The effects of ventilatory apparatus on breathing pattern and gas exchange were studied in normal supine subjects. Using a canopy system, measurements of O2 consumption, CO2 production, tidal volume (VT), frequency (f), minute ventilation, mean inspiratory flow, and inspiratory, and expiratory time (TI and TE) were made and compared to data obtained with the use of a mask (m) and mouthpiece plus noseclip (mp + nc). Use of the m or mp + nc caused a 32.5 and 15.5% increase in VT, respectively, whereas f, TI, and TE remained unchanged. As TI did not change the increase in VT was caused entirely by increased inspiratory flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1980.48.4.577

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 291

Metadata

Authors
Askanazi, J., Silverberg, P. A., Foster, R. J., Hyman, A. I., Milic-Emili, J., & Kinney, J. M.
Venue
Journal of Applied Physiology
Published
1980-04-01
Volume
48
Issue
4
Pages
577-580
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2238867252
Cited by
291
References
0
FWCI
6.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of respiratory apparatus on breathing pattern. https://app.cochat.ai/papers/10.1152/jappl.1980.48.4.577
The paper
Askanazi, J., Silverberg, P. A., Foster, R. J., Hyman, A. I., Milic-Emili, J., & Kinney, J. M. (1980). Effects of respiratory apparatus on breathing pattern. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1980.48.4.577

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.