The DOI matches its Crossref record.
One-step N2-dilution technique for calibrating open-circuit VO2 measuring systems
Abstract
A simple one-step procedure that eliminates the need to calibrate the O2 analyzer or measure the flow past the animal is described for calibrating an open-flow respirometry system. The technique is particularly useful for situations of high ambient humidity and for large or active animals where a mask is employed to capture expired gases. A measured N2 flow is used to calibrate the system. The equations describing the technique are given, and the accuracy of the method is discussed in detail. The errors associated with the technique are compared with those of more conventional procedures and are usually smaller.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The accuracy of the system (± 4%) was validated by N2 dilution tests45.”
From The peacock train does not handicap cursorial locomotor performance (2016) · cites this paper as [45]
Citations
Cited by
Sorted by citations
Energetics of running: a new perspective
Kram, R., & Taylor, C. R. (1990) · Nature · doi:10.1038/346265a0 · Cited by 821
WILSON, R. P., WHITE, C. R., QUINTANA, F., HALSEY, L. G., LIEBSCH, N., MARTIN, G. R., & BUTLER, P. J. (2006) · Journal of Animal Ecology · doi:10.1111/j.1365-2656.2006.01127.x · Cited by 797
Lighton, J. R. B. (2008) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195310610.001.0001 · Cited by 741
Butler, P. J., Green, J. A., Boyd, I. L., & Speakman, J. R. (2004) · Functional Ecology · doi:10.1111/j.0269-8463.2004.00821.x · Cited by 503
Energetic cost of carrying loads: have African women discovered an economic way?
Maloiy, G. M. O., Heglund, N. C., Prager, L. M., Cavagna, G., & Taylor, C. R. (1986) · Nature · doi:10.1038/319668a0 · Cited by 372
Metadata
- Authors
- Fedak, M. A., Rome, L., & Seeherman, H. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1981-09-01
- Volume
- 51
- Issue
- 3
- Pages
- 772-776
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2153755066
- Cited by
- 337
- References
- 0
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 6 · 2023: 5 · 2022: 9 · 2021: 8 · 2020: 6 · 2019: 4 · 2018: 4 · 2017: 7 · 2016: 5 · 2015: 11 · 2014: 10 · 2013: 10 · 2012: 8
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Environmental Science › Ecology › Physiological and biochemical adaptations
- Keywords
- nitrogen dilution, high humidity, measurement error, respiratory gas analysis
- MeSH terms
- Animals, Dogs, Humidity, Mathematics, Methods, Nitrogen, Oxygen Consumption
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review