Breath-by-breath measurement of true alveolar gas exchange

Beaver, W. L., Lamarra, N., Wasserman, K. · 1981 · Journal of Applied Physiology

Abstract

A method has been developed for on-line breath-by-breath calculation of alveolar gas exchange by correcting the gas exchange measured at the mouth for changes in lung gas stores. The corrections are applied to the total lung gas exchange, which is found by directly subtracting expired from inspired volume of each gas. Corrections are made for both breath-to-breath changes in lung volumes and changes in alveolar gas concentrations. The lung volume correction term has the effect of reducing the large error sensitivity of O2 exchange that has, in the past, resulted from direct determination by total lung gas exchange. Error each gas. Corrections are made for both breath-to-breath changes in lung volumes and changes in alveolar gas concentrations. The lung volume correction term has the effect of reducing the large error sensitivity of O2 exchange that has, in the past, resulted from direct determination by total lung gas exchange. Error each gas. Corrections are made for both breath-to-breath changes in lung volumes and changes in alveolar gas concentrations. The lung volume correction term has the effect of reducing the large error sensitivity of O2 exchange that has, in the past, resulted from direct determination by total lung gas exchange. Error sensitivity analysis shows that the effect of inaccuracies due to errors in measuring gas flow or gas concentrations are similar in magnitude to those in the open-circuit method that has traditionally been used. The algorithm for alveolar gas exchange has been implemented in a computer program for on-line respiratory analysis alongside the open-circuit calculation of gas exchange at the mouth that has been used in out laboratory. By use of several experimental studies, it is shown that there are very apparent breath-to-breath differences between the gas exchange measured by the two methods. During metabolic and respiratory transients, these differences often have significant influence on interpretation of the underlying physiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1981.51.6.1662

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 435

Metadata

Authors
Beaver, W. L., Lamarra, N., & Wasserman, K.
Venue
Journal of Applied Physiology
Published
1981-12-01
Volume
51
Issue
6
Pages
1662-1675
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1896447976
Cited by
435
References
8
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Breath-by-breath measurement of true alveolar gas exchange. https://app.cochat.ai/papers/10.1152/jappl.1981.51.6.1662
The paper
Beaver, W. L., Lamarra, N., & Wasserman, K. (1981). Breath-by-breath measurement of true alveolar gas exchange. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1981.51.6.1662

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.