Measurement of pleural pressure in neonates
The DOI matches its Crossref record.
Abstract
The indirect measurement of pleural pressure in neonates is obtained from measurements of esophageal pressure (Pes) with either a liquid-filled catheter or an esophageal balloon-catheter system. The purpose of this investigation was to assess the validity of the water-filled esophageal catheter by comparing the simultaneous changes in Pes and airway opening pressure (Pao) during occluded respiratory efforts. Equal changes in Pes and Pao under this condition indicate that Pes is a valid measurement of pleural pressure. In six healthy unsedated term neonates (aged 2–3 days) we measured Pes in the lower third of the esophagus with a water-filled catheter of eight French gage (FC), which has a 2-mm internal diameter. During occlusions, changes in Pes and Pao were almost identical in magnitude and timing in each body position studied (right lateral, prone, and supine). We conclude that the water-filled 8-FG esophageal catheter gives an accurate measurement of pleural pressure changes in healthy neonates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chervin, R. D., Hedger, K., Dillon, J. E., & Pituch, K. J. (2000) · Sleep Medicine · doi:10.1016/s1389-9457(99)00009-x · Cited by 1,471
Sleep-Disordered Breathing, Behavior, and Cognition in Children Before and After Adenotonsillectomy
Chervin, R. D., Ruzicka, D. L., Giordani, B. J., Weatherly, R. A., Dillon, J. E., Hodges, E. K., Marcus, C. L., & Guire, K. E. (2006) · Pediatrics · doi:10.1542/peds.2005-1837 · Cited by 477
Hyperactivity and Polysomnographic Findings in Children Evaluated for Sleep-Disordered Breathing
Chervin, R. D., & Archbold, K. H. (2001) · Sleep · doi:10.1093/sleep/24.3.313 · Cited by 262
Sleep Onset REM Periods during Multiple Sleep Latency Tests in Patients Evaluated for Sleep Apnea
CHERVIN, R. D., & ALDRICH, M. S. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9905071 · Cited by 98
Chervin, R. D., & Aldrich, M. S. (1998) · Chest · doi:10.1378/chest.113.4.980 · Cited by 74
Diaphragm Pacing for Respiratory Insufficiency
Chervin, R. D., & Guilleminault, C. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00003 · Cited by 56
Metadata
- Authors
- Asher, M. I., Coates, A. L., Collinge, J. M., & Milic-Emili, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-02-01
- Volume
- 52
- Issue
- 2
- Pages
- 491-494
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1892095814
- Cited by
- 107
- References
- 0
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.