Effect of breathing patterns on the perceived magnitude of added loads to breathing
The DOI matches its Crossref record.
Abstract
We have studied the perceived magnitude (psi) of a range of externally added resistive (delta R) and elastic (delta E) loads to breathing while varying the flow rate, tidal volume, and inspiratory duration. The sensory magnitude of an added resistive load increased with both the inspiratory flow rate (P less than 0.001) and the magnitude of the added resistance (P less than 0.01). Similarly, the perceived magnitude of an added elastic load increased with both the tidal volume (P less than 0.001) and the magnitude of the added elastance (P less than 0.01). When inspiratory duration was not controlled, a single relationship was found to hold for both types of load when analyzed as a function of inspiratory airway pressure (P): psi = K . P1.15 (r = 0.94 for delta R); psi = K . p1.10 (r = 0.98 for delta E). When inspiratory duration was controlled, the perceived magnitude of both resistive and elastic loads also increased as the inspiratory duration increased (P less than 0.05). Again, the sensory magnitude was closely related to the airway pressure; but for any given airway pressure the perceptual magnitude also increased as inspiratory duration increased: psi = K . t0.6 (for delta R); psi = K . t0.52 (for delta E). When resistive, elastic, and mixed resistive and elastic loads were presented while keeping inspiratory duration constant, the sensory magnitude was directly related to the airway pressure (r = 0.99) and there was no discernible difference between the types of load. The results suggest that the perceived magnitude of added loads to breathing is directly related to the inspiratory muscle force and its duration (psi = K . P1.3 . t0.56) and indirectly to the added load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Unpleasantness of Perceived Dyspnea Is Processed in the Anterior Insula and Amygdala
von Leupoldt, A., Sommer, T., Kegat, S., Baumann, H. J., Klose, H., Dahme, B., & Büchel, C. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200712-1821oc · Cited by 302
Nava, S., Ferrer, M., Esquinas, A., Scala, R., Groff, P., Cosentini, R., Guido, D., Lin, C.-H., Cuomo, A. M., & Grassi, M. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70009-3 · Cited by 273
Respiratory Muscles and Dyspnea
Killian, K. J., & Jones, N. L. (1988) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(21)00502-5 · Cited by 192
Self-citationPanic Attacks and Perception of Inspiratory Resistive Loads in Chronic Obstructive Pulmonary Disease
Livermore, N., Butler, J. E., Sharpe, L., McBain, R. A., Gandevia, S. C., & McKenzie, D. K. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200711-1700oc · Cited by 113
The science of breathing – the yogic view
Sovik, R. (2000) · Progress in Brain Research · doi:10.1016/s0079-6123(08)62159-7 · Cited by 89
Metadata
- Authors
- Killian, K. J., Bucens, D. D., & Campbell, E. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-03-01
- Volume
- 52
- Issue
- 3
- Pages
- 578-584
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2177321623
- Cited by
- 137
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of breathing patterns on the perceived magnitude of added loads to breathing. https://app.cochat.ai/papers/10.1152/jappl.1982.52.3.578
- The paper
- Killian, K. J., Bucens, D. D., & Campbell, E. J. (1982). Effect of breathing patterns on the perceived magnitude of added loads to breathing. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.3.578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.