Demonstration of failure of body plethysmography in airway obstruction
The DOI matches its Crossref record.
Abstract
To demonstrate the role of extrathoracic airways in the overestimation of lung volumes by body plethysmography in airway obstruction, we induced in six normal subjects an artificial airway stenosis by inflating a balloon in the lower trachea. We measured thoracic gas volume in a body plethysmograph simultaneously from mouth pressure (Pm) vs. plethysmographic volume (Vbox) (TGVm) and from esophageal pressure (Pes) vs. Vbox (TGVes). During control measurements there was no difference between TGVm and TGVes (P greater than 0.1) in any subject. Balloon inflation (B) resulted in a significant (P less than 0.01) decrease of specific airway conductance (sGaw) from a mean value of 0.199 +/- 0.66 (SD) to 0.025 +/- 0.01 cmH2O-1 . s-1. TGVm significantly (P less than 0.02) exceeded TGVes in every subject (mean diff 1.24 +/- 0.56 liters) and Pm lagged behind Pes. In two subjects studied at different levels of airway obstruction we found a significant (P less than 0.05) correlation between TGVm-TGVes difference and sGaw. Bypassing the extrathoracic airways by a cuffed endotracheal tube resulted in each case in a degree of airway obstruction comparable to that during balloon inflation (sGaw 0.019 +/- 0.004 cmH2O-1 . s-1), but no difference between TGVm and TGVes (P greater than 0.1). We conclude that lung volume is overestimated by plethysmography in airway obstruction. The overestimation is due to the presence of a compliant extrathoracic airway, and it probably depends on both the degree of airway obstruction and the value of compliance of the extrathoracic airway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Quantitative Computed Tomography Detects Air Trapping due to Asthma
Newman, K. B., Lynch, D. A., Newman, L. S., Ellegood, D., & Newell, J. D. (1994) · Chest · doi:10.1378/chest.106.1.105 · Cited by 251
ORONASAL OBSTRUCTION, LUNG VOLUMES, AND ARTERIAL OXYGENATION
Rodenstein, D. O., & Stănescu, D. C. (1988) · The Lancet · doi:10.1016/s0140-6736(88)91643-1 · Cited by 212
Self-citationPride, N. B., & Macklem, P. T. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030337 · Cited by 188
Respiratory Muscles in Disease
Tobin, M. J. (1988) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(21)00504-9 · Cited by 177
Measurement of lung volumes by plethysmography
Coates, A., Peslin, R., Rodenstein, D., & Stocks, J. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10061415 · Cited by 174
Self-citationMechanisms, assessment and therapeutic implications of lung hyperinflation in COPD
Rossi, A., Aisanov, Z., Avdeev, S., Di Maria, G., Donner, C. F., Izquierdo, J. L., Roche, N., Similowski, T., Watz, H., Worth, H., et al. (2015) · Respiratory Medicine · doi:10.1016/j.rmed.2015.03.010 · Cited by 121
Comparison of Plethysmographic and Helium Dilution Lung Volumes
O'Donnell, C. R., Bankier, A. A., Stiebellehner, L., Reilly, J. J., Brown, R., & Loring, S. H. (2010) · Chest · doi:10.1378/chest.09-1504 · Cited by 87
Metadata
- Authors
- Rodenstein, D. O., Stanescu, D. C., & Francis, C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-04-01
- Volume
- 52
- Issue
- 4
- Pages
- 949-954
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1888902919
- Cited by
- 115
- References
- 0
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).