Effect of tension and timing of contraction on the blood flow of the diaphragm
The DOI matches its Crossref record.
Abstract
An open-chest animal model was developed to study the diaphragmatic blood flow (Qdi) during bilateral electrophrenic stimulation. Two patterns of stimulation were used, continuous and intermittent, and both patterns were held at various transdiaphragmatic pressures (Pdi). The contractions were nearly isometric and held at an initial length of supine functional residual capacity (FRC). Qdi was measured in six dogs by catheterizing a branch of the diaphragmatic vein and by counting the blood drops with an infrared cell. During continuous contractions Qdi increased as a function of Pdi up to 70 +/- 12 ml . 100 g-1 . min-1 at 20% Pdimax. At higher levels Qdi decreased progressively and approached zero at 75% of Pdimax. A postcontraction hyperemia occurred at Pdi values greater than 20% Pdimax and increased as a function of Pdi. During intermittent contractions Qdi was a unique function of the diaphragmatic tension-time index (TTdi), a product of Pdi times the duty cycle (contraction time/total cycle time). Qdi increased progressively up to a TTdi of 25% Pdimax and decreased above that point toward zero at TTdi of 80% Pdimax. The postcontraction hyperemia appeared at a TTdi of about 15% of Pdimax and increased as a function of TTdi. It is concluded that Qdi is limited beyond a TTdi of about 20% Pdimax, as indicated by the increase in postcontraction hyperamia, and that Qdi is a function of both Pdi and the timing of contraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Fatiguing inspiratory muscle work causes reflex reduction in resting leg blood flow in humans
Sheel, A. W., Derchak, P. A., Morgan, B. J., Pegelow, D. F., Jacques, A. J., & Dempsey, J. A. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0277k.x · Cited by 331
Fatiguing inspiratory muscle work causes reflex sympathetic activation in humans
St Croix, C. M., Morgan, B. J., Wetter, T. J., & Dempsey, J. A. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00493.x · Cited by 298
“These signs of ‘task failure’ were previously shown to coincide first with changes in the frequency spectrum of the EMGdi consistent with impending fatigue (Bellemare et al. 1983) and later with reductions in transdiaphragmatic pressure in response to phrenic nerve stimulation (Yan et al. 1992).”
BackgroundMethodRespiratory Muscles in Disease
Tobin, M. J. (1988) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(21)00504-9 · Cited by 177
Central components of diaphragmatic fatigue assessed by phrenic nerve stimulation
Bellemare, F., & Bigland-Ritchie, B. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.3.1307 · Cited by 170
Self-citation
Metadata
- Authors
- Bellemare, F., Wight, D., Lavigne, C. M., & Grassino, A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1983-06-01
- Volume
- 54
- Issue
- 6
- Pages
- 1597-1606
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2256620892
- Cited by
- 117
- References
- 0
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of tension and timing of contraction on the blood flow of the diaphragm. https://app.cochat.ai/papers/10.1152/jappl.1983.54.6.1597
- The paper
- Bellemare, F., Wight, D., Lavigne, C. M., & Grassino, A. (1983). Effect of tension and timing of contraction on the blood flow of the diaphragm. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1983.54.6.1597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.