Upper airway closing pressures in snorers
The DOI matches its Crossref record.
Abstract
We studied 14 subjects who were selected to represent the broad range of severity of snoring: group A, four subjects who gave a history of snoring only when provoked by nasal obstruction or alcohol intake; group B, six subjects who typically snored for long periods each night; and group C, four subjects who snored heavily all night and who typically experienced a few episodes of obstructive apnea (mean apnea index 4 apneas/h). Low levels of nasal continuous positive airway pressure (CPAP) (range, 2.0–6.0 cmH2O; mean, 4.0 cmH2O) prevented snoring. Nasal occlusion caused upper airway closure during inspiratory efforts in all 14 subjects. There was a relationship between the clinical severity of snoring and the upper airway closing pressure (UACP). Upper airway closure occurred at greater suction pressures in group A than in group C but there was overlap between the three categories. The upper airway was consistently more collapsible in rapid-eye-movement sleep than in non-rapid-eye-movement sleep. There was little evidence of breath-by-breath improvement of upper airway stability during sustained asphyxia, the UACP remaining constant despite marked increases in drive to the diaphragm. In five subjects UACP was measured following alcohol intake. Alcohol reduced upper airway stability in all subjects in a dose-dependent manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Mechanisms of vascular damage in obstructive sleep apnea
Kohler, M., & Stradling, J. R. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.145 · Cited by 513
Pathophysiological mechanisms and therapeutic approaches in obstructive sleep apnea syndrome
Lv, R., Liu, X., Zhang, Y., Dong, N., Wang, X., He, Y., Yue, H., & Yin, Q. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01496-3 · Cited by 477
Upper Airway Collapsibility in Snorers and in Patients with Obstructive Hypopnea and Apnea
Gleadhill, I. C., Schwartz, A. R., Schubert, N., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.6.1300 · Cited by 453
Neurocognitive Impairment in Obstructive Sleep Apnea
Lal, C., Strange, C., & Bachman, D. (2012) · Chest · doi:10.1378/chest.11-2214 · Cited by 406
Metadata
- Authors
- Issa, F. G., & Sullivan, C. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1984-08-01
- Volume
- 57
- Issue
- 2
- Pages
- 528-535
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2116415262
- Cited by
- 143
- References
- 0
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Upper airway closing pressures in snorers. https://app.cochat.ai/papers/10.1152/jappl.1984.57.2.528
- The paper
- Issa, F. G., & Sullivan, C. E. (1984). Upper airway closing pressures in snorers. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1984.57.2.528
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.