CoChat

Reproducibility and accuracy of airway area by acoustic reflection

Brooks, L. J., Castile, R. G., Glass, G. M., Griscom, N. T., Wohl, M. E., Fredberg, J. J. · 1984 · Journal of Applied Physiology
Cited by 80

The DOI matches its Crossref record.

Abstract

To determine the accuracy and reproducibility of measurements of airway area by acoustic reflection (AAAR) we made repeated measurements of tracheal areas in human volunteers, glass airway models, and excised canine tracheae. In 10 adult males, the mean ratio of tracheal AAAR to tracheal areas determined roentgenographically was not significantly different from one (1.06 +/- 0.13 SD). Within-run variability was 10 +/- 4% (CV), mean intrasubject day-to-day variability was 9 +/- 4% (CV). A custom-made mouthpiece is necessary for accurate measurements of AAAR. Mean variability related to differences in mouthpiece construction was 7 +/- 6% (CV). The effect of variations in upper airway and glottic sizes on tracheal AAAR measurements was investigated using glass airway models. In model studies, tracheal AAAR measurements were found to be independent of changes in proximal airway size for glottic apertures greater than or equal to 1 cm2 and upper airway areas less than or equal to 8 cm2. Tracheal area was, however, overestimated by 20% in the rigid-walled glass models. The effects of airway wall rigidity were qualitatively investigated by comparing acoustic and roentgenographic measurements of excised canine tracheae surrounded by either air or petroleum jelly. Differences in the accuracy of measurements of AAAR in vitro and in vivo are probably due to differences in airway wall inertance. These studies suggest that the measurement of AAAR yields an accurate and reproducible result that may be clinically useful for the noninvasive detection of changes in central airway geometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1984.57.3.777

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 80

Metadata

Authors
Brooks, L. J., Castile, R. G., Glass, G. M., Griscom, N. T., Wohl, M. E., & Fredberg, J. J.
Venue
Journal of Applied Physiology
Published
1984-09-01
Volume
57
Issue
3
Pages
777-787
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2463078406
Cited by
80
References
0
FWCI
3.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility and accuracy of airway area by acoustic reflection. https://app.cochat.ai/papers/10.1152/jappl.1984.57.3.777
The paper
Brooks, L. J., Castile, R. G., Glass, G. M., Griscom, N. T., Wohl, M. E., & Fredberg, J. J. (1984). Reproducibility and accuracy of airway area by acoustic reflection. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1984.57.3.777

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.