Gas exchange and lactate anaerobic thresholds: inter- and intraevaluator agreement
The DOI matches its Crossref record.
Abstract
Twenty-four coded graph sets of gas exchange variables and blood lactate concentration (LA) plotted against time at 15-s intervals were analyzed by nine evaluators who determined the gas exchange (ATGE) and LA (ATLA) anaerobic thresholds. In addition, ATGE and ATLA were determined by a linear regression computer program. Agreement between ATGE and ATLA was poor; the median intraclass correlation coefficient (ri) was 0.53. Among evaluators, ATLA agreement (median ri = 0.81) was better than ATGE agreement (median ri = 0.70). In general, the ability of any evaluator to choose similar values from duplicate plots for either ATGE (median ri = 0.97) or ATLA (median ri = 0.995) was good. There was better agreement between the mean ATLA of the evaluators and the computer ATLA (ComLA) (ri = 0.88) than between the mean ATGE of the evaluators and the computer ATGE (ComVE), (ri = 0.58). Agreement between ComVE and ComLA was poor (ri = 0.29). These results suggest that ATGE does not accurately predict ATLA and that different evaluators choose different thresholds from the same data. Further assessment of the validity and precision of ATGE based on breath-by-breath and minute-by-minute data is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Comparison of the ramp versus standard exercise protocols
Myers, J., Buchanan, N., Walsh, D., Kraemer, M., McAuley, P., Hamilton-Wessler, M., & Froelicher, V. F. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80144-5 · Cited by 536
Baba, R., Nagashima, M., Goto, M., Nagano, Y., Yokota, M., Tauchi, N., & Nishibata, K. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00412-3 · Cited by 479
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
Metadata
- Authors
- Gladden, L. B., Yates, J. W., Stremel, R. W., & Stamford, B. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-06-01
- Volume
- 58
- Issue
- 6
- Pages
- 2082-2089
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2275086416
- Cited by
- 129
- References
- 0
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gas exchange and lactate anaerobic thresholds: inter- and intraevaluator agreement. https://app.cochat.ai/papers/10.1152/jappl.1985.58.6.2082
- The paper
- Gladden, L. B., Yates, J. W., Stremel, R. W., & Stamford, B. A. (1985). Gas exchange and lactate anaerobic thresholds: inter- and intraevaluator agreement. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1985.58.6.2082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.