The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved detection of lactate threshold during exercise using a log-log transformation
Abstract
The pattern of arterial lactate concentration ([La-]) increase during incremental exercise was studied using a transformation defined by plotting log([La-]) vs. log(VO2), where VO2 is O2 uptake. A plot of this function exhibits a phase of very slow increase followed by a phase of rapid increase, defining a transition in the underlying relationship between [La-] and VO2. These phases were found to be linear on the log-log plot; linear regression analysis may therefore be used to locate the transition between them (lactate threshold). A transition point was found at a lower VO2 on the semilog plot of log([La-]) vs. VO2. Consideration of the data from all studies led to the conclusion that a more accurate result is provided by the log-log transformation. This analysis shows lactate to have a small, but significant, increase before the transition and to increase beyond it with a power law having an exponent of about 2.9. This result shows that, during incrementally increasing work rate tests, arterial lactate exhibits a threshold behavior, i.e., an abrupt transition from a phase of slow increase to a phase of rapidly accelerating increase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kindermann, W., Simon, G., & Keul, J. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421101 · Cited by 699
Cited by
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Self-citationATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Casaburi, R., Patessio, A., Ioli, F., Zanaboni, S., Donner, C. F., & Wasserman, K. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.1.9 · Cited by 906
Self-citationLactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Metadata
- Authors
- Beaver, W. L., Wasserman, K., & Whipp, B. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-12-01
- Volume
- 59
- Issue
- 6
- Pages
- 1936-1940
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2097870728
- Cited by
- 457
- References
- 1
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved detection of lactate threshold during exercise using a log-log transformation. https://app.cochat.ai/papers/10.1152/jappl.1985.59.6.1936
- The paper
- Beaver, W. L., Wasserman, K., & Whipp, B. J. (1985). Improved detection of lactate threshold during exercise using a log-log transformation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1985.59.6.1936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.