Occlusion pressure and ventilation during sleep in normal humans
The DOI matches its Crossref record.
Abstract
Previous investigation in normal humans has demonstrated reduced ventilation and ventilatory responses to chemical stimuli during sleep. Most have interpreted this to be a product of decreasing central nervous system sensitivity to the normal stimuli that maintain ventilation, whereas other factors such as increasing airflow resistance could also contribute to this reduction in respiration. To improve our understanding of these events, we measured ventilation and occlusion pressures (P0.1) during unstimulated ventilation and rebreathing-induced hypercapnia during wakefulness and non-rapid-eye-movement (NREM) and rapid-eye-movement (REM) sleep. Eighteen subjects (10 males and 8 females) of whom seven were snorers (5 males and 2 females) were studied. Ventilation was reduced during both NREM and REM sleep (P less than 0.05), but this decrement in minute ventilation tended to be greater in snorers than nonsnorers. Unstimulated P0.1, on the other hand, was maintained or increased during sleep in all groups studied, with males and snorers showing the largest increase. The hypercapnic ventilatory response fell during both NREM and REM sleep and tended to be lower during REM than NREM sleep. However, the P0.1 response to hypercapnia during NREM sleep was well maintained at the waking level although the REM response was statistically reduced. These studies suggest that the mechanism of the reduction in ventilation and the hypercapnic ventilatory response seen during sleep, particularly NREM sleep, is likely to be multifactorial and not totally a product of decreasing central respiratory drive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of obstructive sleep apnoea
Deegan, P., & McNicholas, W. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08071161 · Cited by 330
Rapid Eye Movement-Related Sleep-Disordered Breathing
Koo, B. B., Patel, S. R., Strohl, K., & Hoffstein, V. (2008) · Chest · doi:10.1378/chest.08-1311 · Cited by 132
Breath‐holding as a means to estimate the loop gain contribution to obstructive sleep apnoea
Messineo, L., Taranto‐Montemurro, L., Azarbarzin, A., Oliveira Marques, M. D., Calianese, N., White, D. P., Wellman, A., & Sands, S. A. (2018) · The Journal of Physiology · doi:10.1113/jp276206 · Cited by 72
Self-citation
Metadata
- Authors
- White, D. P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1986-10-01
- Volume
- 61
- Issue
- 4
- Pages
- 1279-1287
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2412251886
- Cited by
- 52
- References
- 0
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Occlusion pressure and ventilation during sleep in normal humans. https://app.cochat.ai/papers/10.1152/jappl.1986.61.4.1279
- The paper
- White, D. P. (1986). Occlusion pressure and ventilation during sleep in normal humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1986.61.4.1279
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.