Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing
The DOI matches its Crossref record.
Abstract
The purpose of this study was to investigate the characteristics of a newly developed turbine flowmeter (Alpha Technologies, model VMM-2) for use in an exercise testing system by comparing its measurement of expiratory flow (VE), O2 uptake (VO2), and CO2 output (VCO2) with the Fleisch pneumotachometer. An IBM PC/AT-based breath-by-breath system was developed, with turbine flowmeter and dual-Fleisch pneumotachometers connected in series. A normal subject was tested twice at rest, 100-W, and 175-W of exercise. Expired gas of 24–32 breaths was collected in a Douglas bag. VE was within 4% accuracy for both flowmeter systems. The Fleisch pneumotachometer system had 5% accuracy for VO2 and VCO2 at rest and exercise. The turbine flowmeter system had up to 20% error for VO2 and VCO2 at rest. Errors decreased as work load increased. Visual observations of the flow curves revealed the turbine signal always lagged the Fleisch signal at the beginning of inspiration or expiration. At the end of inspiration or expiration, the turbine signal continued after the Fleisch signal had returned to zero. The “lag-before-start” and “spin-after-stop” effects of the turbine flowmeter resulted in larger than acceptable error for the VO2 and VCO2 measurements at low flow rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Emerging Concepts in the Evaluation of Ventilatory Limitation During Exercise
Johnson, B. D., Weisman, I. M., Zeballos, R. J., & Beck, K. C. (1999) · Chest · doi:10.1378/chest.116.2.488 · Cited by 363
ERS statement on standardisation of cardiopulmonary exercise testing in chronic lung diseases
Radtke, T., Crook, S., Kaltsakas, G., Louvaris, Z., Berton, D., Urquhart, D. S., Kampouras, A., Rabinovich, R. A., Verges, S., Kontopidis, D., et al. (2019) · European Respiratory Review · doi:10.1183/16000617.0101-2018 · Cited by 338
Metadata
- Authors
- Yeh, M. P., Adams, T. D., Gardner, R. M., & Yanowitz, F. G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-09-01
- Volume
- 63
- Issue
- 3
- Pages
- 1289-1295
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2153606162
- Cited by
- 56
- References
- 0
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing. https://app.cochat.ai/papers/10.1152/jappl.1987.63.3.1289
- The paper
- Yeh, M. P., Adams, T. D., Gardner, R. M., & Yanowitz, F. G. (1987). Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1987.63.3.1289
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.