CoChat

Indirect assessment of mucosal surface temperatures in the airways: theory and tests

Ingenito, E. P., Solway, J., McFadden, E. R., Pichurko, B., Bowman, H. F., Michaels, D., Drazen, J. M. · 1987 · Journal of Applied Physiology
Cited by 59

The DOI matches its Crossref record.

Abstract

We developed and tested a method, based on conduction heat transfer analysis, to infer airway mucosal temperatures from airstream temperature-time profiles during breath-hold maneuvers. The method assumes that radial conduction of heat from the mucosal wall to inspired air dominates heat exchange during a breath-hold maneuver and uses a simplified conservation of energy analysis to extrapolate wall temperatures from air temperature vs. time profiles. Validation studies were performed by simultaneously measuring air and wall temperatures by use of a retractable basket probe in the upper airways of human volunteers and intrathoracic airways of paralyzed intubated dogs during breath holding. In both protocols, a good correlation was demonstrated between directly measured wall temperatures and those calculated from adjacent airstream temperature vs. time profiles during a breath hold. We then calculated intrathoracic bronchial wall temperatures from breath-hold airstream temperature-time profiles recorded in normal human subjects after cold air hyperpnea at 30 and 80 l/min. The calculations show airway wall temperatures in the upper intrathoracic airways that are below core body temperature during hyperpnea of frigid air and upper thoracic airways that are cooler than more peripheral airways. The data suggest that the magnitude of local intrathoracic heat/water flux is not represented by heat/water loss measurements at the airway opening. Both the magnitude and locus of heat transport during cold gas hyperventilation vary with changes in inspired gas temperature and minute ventilation; both may be important determinants of airway responses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1987.63.5.2075

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 59

Metadata

Authors
Ingenito, E. P., Solway, J., McFadden, E. R., Pichurko, B., Bowman, H. F., Michaels, D., & Drazen, J. M.
Venue
Journal of Applied Physiology
Published
1987-11-01
Volume
63
Issue
5
Pages
2075-2083
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2412480310
Cited by
59
References
0
FWCI
0.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indirect assessment of mucosal surface temperatures in the airways: theory and tests. https://app.cochat.ai/papers/10.1152/jappl.1987.63.5.2075
The paper
Ingenito, E. P., Solway, J., McFadden, E. R., Pichurko, B., Bowman, H. F., Michaels, D., & Drazen, J. M. (1987). Indirect assessment of mucosal surface temperatures in the airways: theory and tests. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1987.63.5.2075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.