Thermoregulatory, cardiovascular, and muscular factors related to exercise after precooling
The DOI matches its Crossref record.
Abstract
The effect of slightly lowered body temperature on endurance time and possibly related physiological factors was studied in seven male volunteers exercising on a cycle ergometer at an ambient temperature (Ta) of 18 degrees C. Work load was increased to 40% in a stepwise manner (phase I, min 0–16) followed by a period at 80% of peak oxygen consumption (VO2) sustained to exhaustion. On one day, exercise was preceded by a double cold exposure (precooling test, PRET), resulting in a 204-kJ/m2 negative heat storage and a 4 and 0.2 degrees C lower mean skin and core temperature at the start of exercise compared with the control test (CONT). Core temperature dropped further during exercise in PRET. Endurance time at 80% of peak VO2 was increased by 12% (P less than 0.05) in PRET. Heart rate (HR) was decreased throughout PRET (P less than 0.05); oxygen pulse and arteriovenous O2 difference were significantly increased in phase I of PRET, whereas the PRET-CONT differences in stroke volume and cardiac output were not significant. In phase II of PRET (min 16–28, heavy exercise) sweat rate (SR) and heat conductivity, indicating forearm blood flow, were lower (-39%, P less than 0.001; -37%). Pedal rate (PR) was 9% lower (P less than 0.01) in phase II of PRET. At the termination of exercise, PRET-CONT differences in HR, SR, and PR had disappeared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Influence of body temperature on the development of fatigue during prolonged exercise in the heat
González-Alonso, J., Teller, C., Andersen, S. L., Jensen, F. B., Hyldig, T., & Nielsen, B. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.1032 · Cited by 1,129
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
An official European Respiratory Society statement: pulmonary haemodynamics during exercise
Kovacs, G., Herve, P., Barbera, J. A., Chaouat, A., Chemla, D., Condliffe, R., Garcia, G., Grünig, E., Howard, L., Humbert, M., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00578-2017 · Cited by 307
Self-citationIce Slurry Ingestion Increases Core Temperature Capacity and Running Time in the Heat
SIEGEL, R., MATÉ, J., BREARLEY, M. B., WATSON, G., NOSAKA, K., & LAURSEN, P. B. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181bf257a · Cited by 209
“These findings do not correspond with some studies that have demonstrated reduced sweat rates after an external precooling maneuver (18,30).”
Cold water immersion: kill or cure?
Tipton, M. J., Collier, N., Massey, H., Corbett, J., & Harper, M. (2017) · Experimental Physiology · doi:10.1113/ep086283 · Cited by 205
“…body heat content resulted in reduced thermophysiological strain and improved exercise performance (Schmidt & Brück, 1981; Hessemer et al. 1984; Olschewski & Brück, 1988; Lee & Haymes, 1995), although the combination of suboptimal convective cooling and relatively high metabolic rates in…”
Background
Metadata
- Authors
- Olschewski, H., & Bruck, K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-02-01
- Volume
- 64
- Issue
- 2
- Pages
- 803-811
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1918385438
- Cited by
- 134
- References
- 0
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermoregulatory, cardiovascular, and muscular factors related to exercise after precooling. https://app.cochat.ai/papers/10.1152/jappl.1988.64.2.803
- The paper
- Olschewski, H., & Bruck, K. (1988). Thermoregulatory, cardiovascular, and muscular factors related to exercise after precooling. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.64.2.803
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.