The DOI matches its Crossref record.
Variability of resting respiratory drive and timing in healthy subjects
Abstract
Studies of breathing pattern have focused primarily on changes in the mean values of the breathing pattern components, whereas there has been minimal investigation of breath-to-breath variability, which should provide information on the constancy with which respiration is controlled. In this study we examined the variability of breathing pattern both on a breath-to-breath and day-to-day basis by calculating the coefficient of variation (i.e., the standard deviation expressed as a percentage of the mean). By examining breath-to-breath data, we found that the coefficients of variation of tidal volume (VT) and fractional inspiratory time (TI/TT, an index of timing) obtained with an inductive plethysmograph and spirometer were within 1% of each other. Examination of breath-to-breath variability in breathing pattern over a 15-min period in 65 subjects revealed large coefficients of variation, indicating the need to base calculations on a relatively large number of breaths. Less breath-to-breath variability was observed in respiratory frequency [f, 20.8 +/- 11.5% (SD)] and TI/TT (17.9 +/- 6.5%) than in VT (33 +/- 14.9%) and mean inspiratory flow (VT/TI, an index of drive; 31.6 +/- 12.6%; P less than 0.0001). Older subjects (60-81 yr) displayed greater breath-to-breath variability than young subjects (21-50 yr). Use of a mouthpiece did not affect the degree of variability.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Important influence of respiration on human R-R interval power spectra is largely ignored
Brown, T. E., Beightol, L. A., Koh, J., & Eckberg, D. L. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.5.2310 · Cited by 770
Emotions and respiratory patterns: review and critical analysis
Boiten, F. A., Frijda, N. H., & Wientjes, C. J. E. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(94)90027-2 · Cited by 462
Hudgel, D. W., Devadatta, P., Quadri, M., Sioson, E. R., & Hamilton, H. (1993) · Chest · doi:10.1378/chest.104.5.1503 · Cited by 46
Beda, A., Simpson, D. M., Carvalho, N. C., & Carvalho, A. R. S. (2014) · Psychophysiology · doi:10.1111/psyp.12163 · Cited by 43
McFarland (2001) · doi:10.1044/1092-4388(2001/012
Metadata
- Authors
- Tobin, M. J., Mador, M. J., Guenther, S. M., Lodato, R. F., & Sackner, M. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-07-01
- Volume
- 65
- Issue
- 1
- Pages
- 309-317
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1209070443
- Cited by
- 248
- References
- 0
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability of resting respiratory drive and timing in healthy subjects. https://app.cochat.ai/papers/10.1152/jappl.1988.65.1.309
- The paper
- Tobin, M. J., Mador, M. J., Guenther, S. M., Lodato, R. F., & Sackner, M. A. (1988). Variability of resting respiratory drive and timing in healthy subjects. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.65.1.309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.