Temperature profiles with respect to inhomogeneity and geometry of the human body
The DOI matches its Crossref record.
Abstract
Temperature profiles within the human body are highly dependent on the geometry and inhomogeneity of the body. Physical parameters such as density and heat conductivity of the various tissues and variables such as blood flow and metabolic heat production of different organs are spatially distributed and thereby influence the temperature profiles within the human body. Actual physiological knowledge allows one to take into account up to 54 different spatially distributed values for each parameter. An adequate representation of the anatomy of the body requires a spatial three-dimensional grid of at least 0.5-1.0 cm. This is achieved by photogrammetric treatment of three-dimensional anatomic models of the human body. As a first essential result, the simulation system has produced a realistic picture of the topography of temperatures under neutral conditions. Compatibility of reality and simulation was achieved solely on the basis of physical considerations and physiological data base. Therefore the simulation is suited to the extrapolation of temperature profiles that cannot be obtained experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fiala, D., Lomas, K. J., & Stohrer, M. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1957 · Cited by 849
Thermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262
“Werner and Buse (254) gave up the idealized cylindrical symmetry in favor of a three-dimensional (3D) digital representation of the human body including individual organs.”
Witterseh, T., Wyon, D. P., & Clausen, G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00305.x · Cited by 227
Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain
Kim, S., Tathireddy, P., Normann, R. A., & Solzbacher, F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908429 · Cited by 214
Kandlikar, S. G., Perez-Raya, I., Raghupathi, P. A., Gonzalez-Hernandez, J.-L., Dabydeen, D., Medeiros, L., & Phatak, P. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.086 · Cited by 208
“The thermal conductivity and metabolic rates were taken from Werner and Buse [88], and the tumor blood flow andmetabolic heat were obtained from in vivo studies of Gautherie et al.”
Method
Metadata
- Authors
- Werner, J., & Buse, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-09-01
- Volume
- 65
- Issue
- 3
- Pages
- 1110-1118
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1936620128
- Cited by
- 274
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature profiles with respect to inhomogeneity and geometry of the human body. https://app.cochat.ai/papers/10.1152/jappl.1988.65.3.1110
- The paper
- Werner, J., & Buse, M. (1988). Temperature profiles with respect to inhomogeneity and geometry of the human body. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.65.3.1110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.