CoChat

Intrathoracic pressures and left ventricular configuration with respiratory maneuvers

Scharf, S. M., Brown, R., Warner, K. G., Khuri, S. · 1989 · Journal of Applied Physiology
Cited by 44

The DOI matches its Crossref record.

Abstract

In 12 dogs, we examined the correspondence between esophageal (Pes) and pericardial pressures over the anterior, lateral, and inferior left ventricular (LV) surfaces. Pleural pressure was decreased by spontaneous inspiration, Mueller maneuver, and phrenic stimulation and increased by intermittent positive pressure ventilation (IPPV) and positive end-expiratory pressure (PEEP). To separate effects due to blood flow, we analyzed beating and nonbeating hearts. In beating hearts, there were no significant differences between changes in Pes and pericardial pressures. In arrested hearts, increasing LV pressure by 8 Torr increased pericardial pressures by only 3.6 Torr. With IPPV and PEEP, increases in Pes and pericardial pressures were equal in live hearts and in low-volume arrested hearts (LV pressure = 4 Torr). In high-volume arrested hearts (LV pressure = 12 Torr), the increase in pericardial pressure over the anterior LV surface was less than Pes, whereas that over the lateral and inferior LV surfaces was the same as Pes. At high LV volume, in arrested hearts pericardial pressures decreased less than Pes during negative pressure maneuvers. In another six dogs, external LV configuration and volume were measured. In beating hearts during spontaneous inspiration, Mueller maneuver, and phrenic stimulation (endotracheal tube open), septal-lateral dimension and LV volume decreased by approximately 3% (P less than 0.05). This was also true for PEEP. In arrested hearts, septal-lateral dimension and LV volume decreased only with PEEP. We conclude that 1) the relationship between Pes and pericardial pressures is complex and depends on LV volume, local pericardial compliance, and the means by which Pes is changed, 2) changes in measured pericardial pressures did not completely explain changes in LV configuration, and 3) during different respiratory maneuvers, different forces account for the same observed changes in LV volume and configuration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1989.66.1.481

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Scharf, S. M., Brown, R., Warner, K. G., & Khuri, S.
Venue
Journal of Applied Physiology
Published
1989-01-01
Volume
66
Issue
1
Pages
481-491
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2245757118
Cited by
44
References
0
FWCI
2.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.