The DOI matches its Crossref record.
Cervical magnetic stimulation: a new painless method for bilateral phrenic nerve stimulation in conscious humans
Abstract
Assessing diaphragmatic contractility is a common goal in various situations. This assessment is mainly based on static or dynamic maximal voluntary maneuvers and twitch transdiaphragmatic pressures (Pdi) obtained by stimulation of the phrenic nerves (PS). PS eliminates the central components of diaphragmatic activation, but the available techniques of PS remain subject to some limitations. Transcutaneous PS is painful, and needle PS is potentially dangerous. Time-varying magnetic fields can stimulate nervous structures without pain and without adverse effects. In six subjects, we have studied cervical magnetic stimulation (CMS) as a method of PS. We have compared the stimulated Pdi (Pdistim) with the maximal Pdi obtained during static combined expulsive-Mueller maneuver (Pdimax) and with the Pdi generated during a sniff test (Pdisniff). CMS produced twitch Pdi averaging 33.4 +/- 9.7 cmH2O. Pdistim/Pdimax and Pdistim/Pdisniff were 24 +/- 6 and 41 +/- 14%, respectively. These values are comparable to those obtained in other studies with transcutaneous PS. They were highly reproducible in all the subjects. Electromyographic data provided evidence of bilateral maximal stimulation. CMS is a nonspecific method and may stimulate various nervous structures. However, diaphragmatic contraction was elicited by stimulation of the phrenic trunk, since the phrenicodiaphragmatic latencies (less than 7 ms) were in the range of values reported with direct stimulation of the trunk. Cocontraction of neck muscles, including the sternomastoid, was present, but its influence in the CMS-induced Pdi seems minimal. We conclude that magnetic stimulation is an easy, well-tolerated, reproducible safe, and valuable method to assess phrenic conduction and diaphragmatic twitch response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Contractile Properties of the Human Diaphragm during Chronic Hyperinflation
Similowski, T., Yan, S., Gauthier, A. P., Macklem, P. T., & Bellemare, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199109263251304 · Cited by 473
Self-citationRespiratory muscle strength and ventilatory failure in amyotrophic lateral sclerosis
Lyall, R. A. (2001) · Brain · doi:10.1093/brain/124.10.2000 · Cited by 384
Exercise-induced respiratory muscle fatigue: implications for performance
Romer, L. M., & Polkey, M. I. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01157.2007 · Cited by 352
Diaphragm strength in chronic obstructive pulmonary disease.
Polkey, M. I., Kyroussis, D., Hamnegard, C. H., Mills, G. H., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.5.8912741 · Cited by 266
Metadata
- Authors
- Similowski, T., Fleury, B., Launois, S., Cathala, H. P., Bouche, P., & Derenne, J. P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1989-10-01
- Volume
- 67
- Issue
- 4
- Pages
- 1311-1318
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1933818409
- Cited by
- 324
- References
- 0
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cervical magnetic stimulation: a new painless method for bilateral phrenic nerve stimulation in conscious humans. https://app.cochat.ai/papers/10.1152/jappl.1989.67.4.1311
- The paper
- Similowski, T., Fleury, B., Launois, S., Cathala, H. P., Bouche, P., & Derenne, J. P. (1989). Cervical magnetic stimulation: a new painless method for bilateral phrenic nerve stimulation in conscious humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1989.67.4.1311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.