The DOI matches its Crossref record.
Mechanical impedances of lungs and chest wall in the cat
Abstract
In nine anesthetized and paralyzed cats, the mechanical impedances of the total respiratory system (Zrs) and the lungs (ZL) were measured with small-volume pseudorandom forced oscillations between 0.2 and 20 Hz. ZL was measured after thoracotomy, and chest wall impedance (Zw) was calculated as Zw = Zrs-ZL. All impedances were determined by using input airflow [input impedance (Zi)] and output flow measured with a body box [transfer impedance (Zt)]. The differences between Zi and Zt were small for Zrs and negligible for ZL. At 0.2 Hz, the real and imaginary parts of ZL amounted to 33 +/- 4 and 35 +/- 3% (SD), respectively, of Zrs. Up to 8 Hz, all impedances were consistent with a model containing a frequency-independent resistance and inertance and a constant-phase tissue part (G-jH)/omega alpha, where G and H are coefficients for damping and elastance, respectively, omega is angular frequency, and alpha determines the frequency dependence of the real and imaginary parts. G/H was higher for Zw than for ZL (0.29 +/- 0.05 vs. 0.22 +/- 0.04, P less than 0.01). In four cats, the amplitude dependence of impedances was studied: between oscillation volumes of 0.8 and 3 ml, GL, HL, Gw, and Hw decreased on average by 3, 9, 26, and 29%, respectively, whereas the change in G/H was small for both ZL (7%) and Zw (-4%). The values of H were two to three times higher than the quasistatic elastances estimated with greater volume changes (greater than 20 ml).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Expression of therapeutic proteins after delivery of chemically modified mRNA in mice
Kormann, M. S. D., Hasenpusch, G., Aneja, M. K., Nica, G., Flemmer, A. W., Herber-Jonat, S., Huppmann, M., Mays, L. E., Illenyi, M., Schams, A., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1733 · Cited by 733
The role of fractional calculus in modeling biological phenomena: A review
Ionescu, C., Lopes, A., Copot, D., Machado, J. A. T., & Bates, J. H. T. (2017) · Communications in Nonlinear Science and Numerical Simulation · doi:10.1016/j.cnsns.2017.04.001 · Cited by 729
A Survey of Fractional-Order Circuit Models for Biology and Biomedicine
Freeborn, T. J. (2013) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2013.2265797 · Cited by 353
Wale, M. K. T. Ć., Holt, P. G., & Sly, P. D. (2000) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb.22.5.3710 · Cited by 276
Metadata
- Authors
- Hantos, Z., Adamicza, A., Govaerts, E., & Daroczy, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1992-08-01
- Volume
- 73
- Issue
- 2
- Pages
- 427-433
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2408477343
- Cited by
- 162
- References
- 0
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical impedances of lungs and chest wall in the cat. https://app.cochat.ai/papers/10.1152/jappl.1992.73.2.427
- The paper
- Hantos, Z., Adamicza, A., Govaerts, E., & Daroczy, B. (1992). Mechanical impedances of lungs and chest wall in the cat. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1992.73.2.427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.