Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy
The DOI matches its Crossref record.
Abstract
A noninvasive method of measuring hemoglobin flow through an organ by near-infrared spectroscopy (NIRS) is described that allows blood flow to be calculated. The method is derived from the Fick principle and uses a small change in arterial oxyhemoglobin concentration (brought about by a change in the fractional inspired O2 concentration) as an intravascular tracer. Changes in deoxyhemoglobin and oxyhemoglobin concentrations are quantified by monitoring variations in the absorption of near-infrared light in the organ, thus providing a measure of tracer accumulation. The tracer input function is calculated from the change in arterial O2 saturation, measured by pulse oximetry. The method was used to determine hemoglobin flow in the forearms of six healthy young adults on 10 occasions. Forearm hemoglobin flow ranged from 22.5 to 82.6 mumol.l-1.min-1. Calculated forearm blood flow ranged from 1.01 to 4.01 ml.100 g-1.min-1. For comparison, forearm blood flow was measured by venous occlusion plethysmography, and the relation between flow calculated by NIRS (y) and plethysmography (x) was y = 0.93x + 0.30 (r2 = 0.95). The mean difference between the methods was 0.14 ml.100 g-1.min-1. The technique may be widely applicable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Noninvasive monitoring of peripheral perfusion
Lima, A., & Bakker, J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2790-2 · Cited by 409
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Near-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Metadata
- Authors
- Edwards, A. D., Richardson, C., van der Zee, P., Elwell, C., Wyatt, J. S., Cope, M., Delpy, D. T., & Reynolds, E. O.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-10-01
- Volume
- 75
- Issue
- 4
- Pages
- 1884-1889
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2254999223
- Cited by
- 153
- References
- 0
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy. https://app.cochat.ai/papers/10.1152/jappl.1993.75.4.1884
- The paper
- Edwards, A. D., Richardson, C., van der Zee, P., Elwell, C., Wyatt, J. S., Cope, M., Delpy, D. T., & Reynolds, E. O. (1993). Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.75.4.1884
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.