Distinguishing between aerobic and anaerobic appearance of dissolved CO2 in intestine during low flow
The DOI matches its Crossref record.
Abstract
Increased intestinal mucosal PCO2 is used to detect the condition of inadequate O2 delivery, i.e., “dysoxia.” However, mucosal PCO2 (PmCO2) can arise from oxidative phosphorylation, in which case it would detect metabolism that persists as blood stagnates, and/or from HCO3- neutralization by anaerobically produced metabolic acid, in which event it could represent dysoxia. We measured portal venous PCO2 (PVCO2) directly and PmCO2 indirectly with saline-filled CO2-permeable Silastic balloon tonometers in the intestinal lumen during progressive lethal cardiac tamponade in six pentobarbital-anesthetized dogs. PVCO2 and PmCO2 were relatively constant, differing by approximately 10 Torr until an O2 delivery (DO2) of approximately 1.3 ml.kg-1.min-1 was reached, below which PVCO2 and PmCO2 diverged strikingly, achieving a final difference of 78.7 +/- 35.81 (SD) Torr. To determine whether PCO2 arose from aerobic or anaerobic metabolism, we used the Dill nomogram to predict venous oxyhemoglobin (HbO2v) saturation (%HbO2v) from PVCO2. Portal venous %HbO2 predicted by the Dill nomogram agreed well with measured portal venous %HbO2 during all but the final values, indicating primarily aerobic appearance of PCO2 in venous blood, suggesting that portions of intestine that remained perfused at very low flow produced dissolved CO2 mainly by oxidative phosphorylation. As PmCO2 increased below critical DO2, however, predicted mucosal %HbO2v became strikingly negative, achieving a final value of -192 +/- 106.1%, indicating anaerobic dissolved CO2 production in mucosa. We conclude that PCO2 measured in intestinal lumen can be used to detect dysoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Levy, B., Bollaert, P.-E., Charpentier, C., Nace, L., Audibert, G., Bauer, P., Nabet, P., & Larcan, A. (1997) · Intensive Care Medicine · doi:10.1007/s001340050329 · Cited by 444
Monitoring the microcirculation in the critically ill patient: current methods and future approaches
De Backer, D., Ospina-Tascon, G., Salgado, D., Favory, R., Creteur, J., & Vincent, J.-L. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2005-3 · Cited by 426
The importance of the gastrointestinal system in the pathogenesis of heart failure
Krack, A., Sharma, R., Figulla, H. R., & Anker, S. D. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi389 · Cited by 280
“12 Cellular CO2 levels depend on the balance between CO2 production via both aerobic and anaerobic metabolism and CO2 removal by blood flow from the particular tissue bed and alveolar ventilation.(13) CO2 elimination by the lungs depends upon alveolar ventilation and perfusion, which determines how much returns to the…”
BackgroundMarik, P. E. (2001) · Chest · doi:10.1378/chest.120.3.923 · Cited by 170
Exercise induces gastric ischemia in healthy volunteers: a tonometry study
Otte, J. A., Oostveen, E., Geelkerken, R. H., Groeneveld, A. B. J., & Kolkman, J. J. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.866 · Cited by 138
“Nevertheless, we cannot exclude ischemia and anaerobic metabolism in the gastric mucosa even at gradients lower than the critical values reported by Schlichtig and Bowles.”
BackgroundResultInfluential
Metadata
- Authors
- Schlichtig, R., & Bowles, S. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-06-01
- Volume
- 76
- Issue
- 6
- Pages
- 2443-2451
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2152063232
- Cited by
- 241
- References
- 0
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.