Ventilatory variability induced by spontaneous variations of PaCO2 in humans
The DOI matches its Crossref record.
Abstract
We tested the hypothesis that breath-to-breath variations in arterial CO2 partial pressure (PaCO2) during spontaneous breathing of awake humans cause a significant portion of spontaneous ventilatory variability (including periodic oscillations). This hypothesis was tested in two ways. First, using a recently developed adaptive PaCO2 buffering technique we reduced the spontaneous variability in PaCO2 of six awake normal young human subjects during hyperoxia and observed a corresponding decrease in their breath-to-breath ventilatory variations. Second, we predicted the ventilatory responses to CO2 disturbances by using a model of chemical control of ventilation, both examining the hyperoxic condition (similar to experimental studies) and predicting the responses to CO2 variations of a normal subject breathing room air. In all experimental and theoretical studies, we found that small random disturbances to PaCO2 have significant effects on ventilation, including the potential for such PaCO2 disturbances to elicit oscillatory fluctuations in ventilation even though the ventilatory chemical control system was stable (i.e., a brief disturbance to PaCO2 did not elicit sustained ventilatory oscillations). On the basis of these results we propose that the stability of chemoreflex ventilatory control loops depends on both “loop gain” factors and the characteristics of random disturbances to PaCO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Birn, R. M., Diamond, J. B., Smith, M. A., & Bandettini, P. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.048 · Cited by 1,358
Opioids and the control of respiration
Pattinson, K. T. S. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen094 · Cited by 793
Resting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
“Breath-to-breath variations in arterial CO2 partial pressure during spontaneous breathing lead to changes in respiration rate (Modarreszadeh and Bruce, 1994).”
Wise, R. G., Ide, K., Poulin, M. J., & Tracey, I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.025 · Cited by 664
“Fluctuations in resting PET CO 2 have been observed principally in the range 0 – 0.05 Hz (Modarreszadeh and Bruce, 1994; Van den Aardweg and Karemaker, 2002).”
BackgroundInfluentialBirn, R. M., Smith, M. A., Jones, T. B., & Bandettini, P. A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.059 · Cited by 645
The role of physiological noise in resting-state functional connectivity
Birn, R. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.016 · Cited by 359
Determinants of ventilatory instability and variability
Khoo, M. C. K. (2000) · Respiration Physiology · doi:10.1016/s0034-5687(00)00157-2 · Cited by 304
Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI
Chang, C., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.048 · Cited by 292
Functional Magnetic Resonance Imaging Methods
Chen, J. E., & Glover, G. H. (2015) · Neuropsychology Review · doi:10.1007/s11065-015-9294-9 · Cited by 212
“…of breathing depth and rate lead to altered levels of arterial CO 2 , a potent vasodilator modulating blood flow and consequently the amplitude of BOLD signals (Modarreszadeh and Bruce 1994; Van den Aardweg and Karemaker 2002; Wise et al. 2004; Birn et al. 2006, 2008a, b; Chang and Glover 2009).”
BackgroundPhysiologic instability in panic disorder and generalized anxiety disorder
Wilhelm, F. H., Trabert, W., & Roth, W. T. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01000-3 · Cited by 180
PATTINSON, K., MITSIS, G., HARVEY, A., JBABDI, S., DIRCKX, S., MAYHEW, S., ROGERS, R., TRACEY, I., & WISE, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.007 · Cited by 163
“Spontaneous fluctuations in PaCO 2 occur in humans at rest (Crosby and Robbins, 2003; Modarreszadeh and Bruce, 1994; Van den Aardweg and Karemaker, 2002).”
Metadata
- Authors
- Modarreszadeh, M., & Bruce, E. N.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-06-01
- Volume
- 76
- Issue
- 6
- Pages
- 2765-2775
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2185832297
- Cited by
- 60
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.