The DOI matches its Crossref record.
Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung
Abstract
Both ventilator pattern and neutrophil activation influence lung injury in adult respiratory distress syndrome (ARDS). We therefore questioned whether ventilator pattern independently affects neutrophil accumulation and function in early ARDS. Thirty-five New Zealand White rabbits were anesthetized, paralyzed, and prepared using sterile techniques. Fifteen surfactant-depleted animals were randomized and ventilated for 4 h using high-frequency oscillatory ventilation (HFO) at 15 Hz with an inspired O2 fraction = 1.0 and arterial PO2 (PaO2) > 400 Torr (a pattern known to reverse atelectasis) or conventional mechanical ventilation (CMV) with PaO2 = 80–100 Torr (a pattern with some atelectasis despite positive end-expiratory pressure). Eight normal animals on CMV with PaO2 > 400 Torr served as a reference group (NorCMV). NorCMV animals progressively increased circulating polymorphonuclear neutrophil (PMN) numbers and had minor pressure-volume curve alterations but no other significant changes. Lavaged CMV animals developed the characteristic gas exchange and marked pressure-volume curve abnormalities of ARDS. Circulating PMNs remained constant but developed decreased chemotactic activity, whereas lung neutrophil numbers increased significantly (P = 0.0002) and had substantially enhanced chemiluminescence (P = 0.0003 vs. NorCMV animals). Although lavaged HFO animals accumulated an intermediate number of lung neutrophils (lung myeloperoxidase > NorCMV animals; P = 0.003), the chemiluminescence and chemotaxis of these PMNs were the same as in cells from NorCMV animals. We concluded that both the degree of neutrophil activation and lung injury can be minimized by preventing cyclic alveolar/airway expansion and collapse in the surfactant-deficient lung by use of appropriate ventilator patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Multiple System Organ Failure: Is Mechanical Ventilation a Contributing Factor?
SLUTSKY, A. S., & TREMBLAY, L. N. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9709092 · Cited by 836
Matthay, M. A., & Zimmerman, G. A. (2005) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.f305 · Cited by 642
Metadata
- Authors
- Sugiura, M., McCulloch, P. R., Wren, S., Dawson, R. H., & Froese, A. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-09-01
- Volume
- 77
- Issue
- 3
- Pages
- 1355-1365
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2264634891
- Cited by
- 170
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung. https://app.cochat.ai/papers/10.1152/jappl.1994.77.3.1355
- The paper
- Sugiura, M., McCulloch, P. R., Wren, S., Dawson, R. H., & Froese, A. B. (1994). Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1994.77.3.1355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.