Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record.

Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung

Sugiura, M., McCulloch, P. R., Wren, S., Dawson, R. H., Froese, A. B.·1994·Journal of Applied Physiology

Abstract

Both ventilator pattern and neutrophil activation influence lung injury in adult respiratory distress syndrome (ARDS). We therefore questioned whether ventilator pattern independently affects neutrophil accumulation and function in early ARDS. Thirty-five New Zealand White rabbits were anesthetized, paralyzed, and prepared using sterile techniques. Fifteen surfactant-depleted animals were randomized and ventilated for 4 h using high-frequency oscillatory ventilation (HFO) at 15 Hz with an inspired O2 fraction = 1.0 and arterial PO2 (PaO2) > 400 Torr (a pattern known to reverse atelectasis) or conventional mechanical ventilation (CMV) with PaO2 = 80–100 Torr (a pattern with some atelectasis despite positive end-expiratory pressure). Eight normal animals on CMV with PaO2 > 400 Torr served as a reference group (NorCMV). NorCMV animals progressively increased circulating polymorphonuclear neutrophil (PMN) numbers and had minor pressure-volume curve alterations but no other significant changes. Lavaged CMV animals developed the characteristic gas exchange and marked pressure-volume curve abnormalities of ARDS. Circulating PMNs remained constant but developed decreased chemotactic activity, whereas lung neutrophil numbers increased significantly (P = 0.0002) and had substantially enhanced chemiluminescence (P = 0.0003 vs. NorCMV animals). Although lavaged HFO animals accumulated an intermediate number of lung neutrophils (lung myeloperoxidase > NorCMV animals; P = 0.003), the chemiluminescence and chemotaxis of these PMNs were the same as in cells from NorCMV animals. We concluded that both the degree of neutrophil activation and lung injury can be minimized by preventing cyclic alveolar/airway expansion and collapse in the surfactant-deficient lung by use of appropriate ventilator patterns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1994.77.3.1355

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
Sugiura, M., McCulloch, P. R., Wren, S., Dawson, R. H., & Froese, A. B.
Venue
Journal of Applied Physiology
Published
1994-09-01
Volume
77
Issue
3
Pages
1355-1365
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2264634891
Cited by
170
References
0
FWCI
2.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung. https://app.cochat.ai/papers/10.1152/jappl.1994.77.3.1355
The paper
Sugiura, M., McCulloch, P. R., Wren, S., Dawson, R. H., & Froese, A. B. (1994). Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1994.77.3.1355

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.