Heart rate and blood pressure variabilities during graded head-up tilt
The DOI matches its Crossref record.
Abstract
We investigated the responses of the frequency components of heart rate (HR) and blood pressure (BP) variabilities to progressive changes in autonomic activity induced by the graded head-up tilt technique in 12 normal subjects (age 19–27 yr) under the condition of frequency-controlled respiration (0.25 Hz). During low-level tilt (0–30 degrees), the R-R interval was unchanged and the amplitude of the high-frequency (HF; 0.25 Hz) component of HR variability showed only a slight insignificant decrease. The amplitude of the low-frequency (LF; 0.04–0.15 Hz) component of HR variability increased progressively as the angle increased (P < 0.05). During high-level tilt (30–90 degrees), the R-R interval and the HF amplitude of HR variability decreased progressively with tilt angle (P < 0.001 for both). The LF amplitude of HR variability peaked at a tilt angle of 30 degrees. The LF-to-HF ratio of HR variability and the LF amplitude of systolic and diastolic BP variabilities increased progressively as the tilt angle increased from 0 to 60 degrees (P < 0.001), although systolic and diastolic BPs were unchanged. These results suggest that mixed autonomic responses to orthostatic stress, which are thought to be mediated by both cardiopulmonary and arterial baroreflex mechanisms, can be distinguished by changes in the frequency components of HR and BP variabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
Sympathovagal Balance: A Critical Appraisal
Eckberg, D. L. (1997) · Circulation · doi:10.1161/01.cir.96.9.3224 · Cited by 1,087
Reyes del Paso, G. A., Langewitz, W., Mulder, L. J. M., van Roon, A., & Duschek, S. (2013) · Psychophysiology · doi:10.1111/psyp.12027 · Cited by 954
Human responses to upright tilt: a window on central autonomic integration
Cooke, W. H., Hoag, J. B., Crossman, A. A., Kuusela, T. A., Tahvanainen, K. U. O., & Eckberg, D. L. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0617t.x · Cited by 506
Quintana, D. S., Alvares, G. A., & Heathers, J. A. J. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.73 · Cited by 420
“However, work frequently combines and compares time and frequency domain methods of HRV.”
Influential
Metadata
- Authors
- Mukai, S., & Hayano, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1995-01-01
- Volume
- 78
- Issue
- 1
- Pages
- 212-216
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2179287879
- Cited by
- 112
- References
- 0
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart rate and blood pressure variabilities during graded head-up tilt. https://app.cochat.ai/papers/10.1152/jappl.1995.78.1.212
- The paper
- Mukai, S., & Hayano, J. (1995). Heart rate and blood pressure variabilities during graded head-up tilt. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1995.78.1.212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.