CoChat

Effect of hindlimb unloading on rat soleus fiber force, stiffness, and calcium sensitivity

McDonald, K. S., Fitts, R. H. · 1995 · Journal of Applied Physiology
Cited by 102

The DOI matches its Crossref record.

Abstract

The purpose of this study was to examine the time course of change in soleus muscle fiber peak force (N), tension (Po, kN/m2), elastic modulus (Eo), and force-pCa and stiffness-pCa relationships. After 1, 2, or 3 wk of hindlimb unloading (HU), single fibers were isolated and placed between a motor arm and a transducer, and fiber diameter, peak absolute force, Po, Eo, and force-pCa and stiffness-pCa relationships were characterized. One week of HU resulted in a significant reduction in fiber diameter (68 +/- 2 vs 57 +/- 1 microns), force (3.59 +/- 0.15 vs. 2.19 +/- 0.12 x 10(-4) N), Po (102 +/- 4 vs. 85 +/- 2 kN/m2), and Eo (1.96 +/- 0.12 vs. 1.37 +/- 0.13 x 10(7) N/m2), and 2 wk of HU caused a further decline in fiber diameter (45 +/- 1 microns), force (1.31 +/- 0.06 x 10(-4) N), and Eo (0.96 +/- 0.09 x 10(7) N/m2). Although the mean fiber diameter and absolute force continued to decline through 3 wk of HU, Po recovered to values not significantly different from control. The Po/Eo ratio was significantly increased after 1 (5.5 +/- 0.3 to 7.1 +/- 0.6), 2, and 3 wk of HU, and the 2-wk (9.5 +/- 0.4) and 3-wk (9.4 +/- 0.8) values were significantly greater than the 1-wk values. The force-pCa and stiffness-pCa curves were shifted rightward after 1, 2, and 3 wk of HU. At 1 wk of HU, the Ca2+ sensitivity of isometric force, assessed by Ca2+ concentration required for half-maximal force, was increased from the control value of 1.83 +/- 0.12 to 2.30 +/- 0.10 microM. In conclusion, after HU, the decrease in soleus fiber Po can be explained by a reduction in the number of myofibrillar cross bridges per cross-sectional area. Our working hypothesis is that the loss of contractile protein reduces the number of cross bridges per cross-sectional area and increases the filament lattice spacing. The increased spacing reduces cross-bridge force and stiffness, but Po/Eo increases because of a quantitatively greater effect on stiffness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1995.79.5.1796

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
McDonald, K. S., & Fitts, R. H.
Venue
Journal of Applied Physiology
Published
1995-11-01
Volume
79
Issue
5
Pages
1796-1802
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2112694892
Cited by
102
References
0
FWCI
1.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.