Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record.

Effects of hydrostatic pressure on matrix synthesis in different regions of the intervertebral disk

Ishihara, H., McNally, D. S., Urban, J. P., Hall, A. C.·1996·Journal of Applied Physiology

Abstract

The intervertebral disk is routinely subjected to compressive loads that alter with posture and muscle activity and can produce pressures = 2 MPa in human lumbar disks in vivo (A. Nachemson and G. Elfstrom. Scand. J. Rehabil. Med. 2, Suppl. 1:1-40, 1979; A. Nachemson and J. M. Morris. J. Bone Jt. Surg. Am. Vol. 46A: 1077-1092, 1964). We measured the effect of load on hydrostatic pressures in bovine caudal disks. With increase in applied load, pressure increased linearly in the nucleus and inner annulus. The resting pressure measured after slaughter (0.19 +/- 0.05 MPa) and the pressure at failure (34 MPa, estimated from the vertebrae/disk segment failure load of 7,430 +/- 590 N) define the limits that can occur in vivo. Because hydrostatic pressure influences matrix synthesis in articular cartilage, we have examined the effects of pressures in the range 1-10 MPa applied for 20 s or 2 h on proteoglycan synthesis in bovine caudal and human lumbar intervertebral disks in vitro. In the nucleus pulposus and inner annulus of bovine disks, application of hydrostatic pressure in the range of 1-7.5 MPa for only 20 s stimulated matrix synthesis over the following 2 h at atmospheric pressure. The maximum stimulation in the bovine disks was seen in the inner annulus after application of 2.5 MPa, where proteoglycan synthesis rates doubled. Exposure to 2.5 MPa also stimulated synthesis in the nucleus pulposus of human disks taken at surgery, whereas 7.5 MPa inhibited synthesis in five out of six specimens. With 2-h continuous exposure to the same levels of pressure, no stimulation was seen in the nucleus of bovine disks, and significant stimulation was only observed at 5.0 MPa in the inner annulus. Exposure to 10 MPa for either 20 s or 2 h inhibited proteoglycan synthesis in these regions of the disks. In contrast, in the outer annulus, where loading does not lead to a rise in hydrostatic pressure in vivo, there was no significant response to hydrostatic pressure over the range of 1-10 MPa in bovine or human disks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1996.80.3.839

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 242

Metadata

Authors
Ishihara, H., McNally, D. S., Urban, J. P., & Hall, A. C.
Venue
Journal of Applied Physiology
Published
1996-03-01
Volume
80
Issue
3
Pages
839-846
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1897804960
Cited by
242
References
0
FWCI
3.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of hydrostatic pressure on matrix synthesis in different regions of the intervertebral disk. https://app.cochat.ai/papers/10.1152/jappl.1996.80.3.839
The paper
Ishihara, H., McNally, D. S., Urban, J. P., & Hall, A. C. (1996). Effects of hydrostatic pressure on matrix synthesis in different regions of the intervertebral disk. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.80.3.839

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.