The DOI matches its Crossref record.
Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy
Abstract
The purpose of this study was to determine whether the initial rate of hemoglobin and myoglobin deoxygenation during immediate postexercise ischemia, a reflection of muscle O2 consumption (VO2mus), can be a quantitative measure of muscle oxidative metabolism. The finger flexor muscles of five healthy men (aged 25-31 yr) were monitored by 31P-magnetic resonance spectroscopy for changes in phosphocreatine (PCr), Pi, and pH. Tests were conducted during 15 min of cuff ischemia and during 5 min of submaximal isotonic grip exercise at 10, 20, 30, and 40% of maximal voluntary contraction, one contraction every 4 s. The VO2mus changes were also monitored by near-infrared spectroscopy with continuous wave. The VO2mus during exercise was expressed relative to the resting value. The resting metabolic rate, calculated from the PCr breakdown rate after complete O2 depletion, was 0.0010 (SD) mM ATP/s. During submaximal exercise (pH > 6.9), the VO2mus increased with a rise in intensity (0.036 +/- 0.011, 0.054 +/- 0.016, 0.062 +/- 0.012, and 0.067 +/- 0.020 mM ATP/s during 10, 20, 30, and 40% maximal voluntary contraction, respectively) and showed significant correlation with changes in both calculated ADP and PCr values (r2 = 0.98 and r2 = 0.99, respectively). In conclusion, because of the significant correlation with regulatory metabolites (ADP and PCr) of oxidative phosphorylation, O2 decline rate in immediate postexercise ischemia determined by near-infrared spectroscopy with continuous wave can be utilized for the quantitative evaluation of localized muscle oxidative metabolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
Metadata
- Authors
- Hamaoka, T., Iwane, H., Shimomitsu, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Kurosawa, Y., & Chance, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-09-01
- Volume
- 81
- Issue
- 3
- Pages
- 1410-1417
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1838595539
- Cited by
- 280
- References
- 0
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy. https://app.cochat.ai/papers/10.1152/jappl.1996.81.3.1410
- The paper
- Hamaoka, T., Iwane, H., Shimomitsu, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Kurosawa, Y., & Chance, B. (1996). Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.81.3.1410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.