Combined heart rate and activity improve estimates of oxygen consumption and carbon dioxide production rates
The DOI matches its Crossref record.
Abstract
Moon, Jon K., and Nancy F. Butte. Combined heart rate and activity improve estimates of oxygen consumption and carbon dioxide production rates. J. Appl. Physiol.81(4): 1754–1761, 1996.—Oxygen consumption (V˙o 2) and carbon dioxide production (V˙co 2) rates were measured by electronically recording heart rate (HR) and physical activity (PA). Mean daily V˙o 2 andV˙co 2 measurements by HR and PA were validated in adults ( n = 10 women and 10 men) with room calorimeters. Thirteen linear and nonlinear functions of HR alone and HR combined with PA were tested as models of 24-h V˙o 2 andV˙co 2. Mean sleepV˙o 2 andV˙co 2 were similar to basal metabolic rates and were accurately estimated from HR alone [respective mean errors were −0.2 ± 0.8 (SD) and −0.4 ± 0.6%]. The range of prediction errors for 24-h V˙o 2 andV˙co 2 was smallest for a model that used PA to assign HR for each minute to separate active and inactive curves (V˙o 2, −3.3 ± 3.5%; V˙co 2, −4.6 ± 3%). There were no significant correlations betweenV˙o 2 orV˙co 2 errors and subject age, weight, fat mass, ratio of daily to basal energy expenditure rate, or fitness. V˙o 2,V˙co 2, and energy expenditure recorded for 3 free-living days were 5.6 ± 0.9 ml ⋅ min−1⋅ kg−1, 4.7 ± 0.8 ml ⋅ min−1⋅ kg−1, and 7.8 ± 1.6 kJ/min, respectively. Combined HR and PA measured 24-h V˙o 2 andV˙co 2 with a precision similar to alternative methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Measurement Issues in the Assessment of Physical Activity in Children
Welk, G. J., Corbin, C. B., & Dale, D. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082788 · Cited by 782
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Metadata
- Authors
- Moon, J. K., & Butte, N. F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-10-01
- Volume
- 81
- Issue
- 4
- Pages
- 1754-1761
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2154997231
- Cited by
- 68
- References
- 0
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined heart rate and activity improve estimates of oxygen consumption and carbon dioxide production rates. https://app.cochat.ai/papers/10.1152/jappl.1996.81.4.1754
- The paper
- Moon, J. K., & Butte, N. F. (1996). Combined heart rate and activity improve estimates of oxygen consumption and carbon dioxide production rates. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.81.4.1754
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.