CoChat

Aerobic fitness effects on exercise-induced low-frequency diaphragm fatigue

Babcock, Mark A., Pegelow, David F., Johnson, Bruce D., Dempsey, Jerome A. · 1996 · Journal of Applied Physiology
Cited by 93

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Babcock, Mark A., David F. Pegelow, Bruce D. Johnson, and Jerome A. Dempsey. Aerobic fitness effects on exercise-induced low-frequency diaphragm fatigue. J. Appl. Physiol. 81(5): 2156–2164, 1996.—We used bilateral phrenic nerve stimulation (BPNS; at 1, 10, and 20 Hz at functional residual capacity) to compare the amount of exercise-induced diaphragm fatigue between two groups of healthy subjects, a high-fit group [maximal O 2 consumption (V˙o 2 max) = 69.0 ± 1.8 ml ⋅ kg−1 ⋅ min−1, n = 11] and a fit group (V˙o 2 max = 50.4 ± 1.7 ml ⋅ kg−1 ⋅ min−1, n = 13). Both groups exercised at 88–92% V˙o 2 max for about the same duration (15.2 ± 1.7 and 17.9 ± 2.6 min for high-fit and fit subjects, respectively, P > 0.05). The supramaximal BPNS test showed a significant reduction ( P< 0.01) in the BPNS transdiaphragmatic pressure (Pdi) immediately after exercise of −23.1 ± 3.1% for the high-fit group and −23.1 ± 3.8% ( P > 0.05) for the fit group. Recovery of the BPNS Pdi took 60 min in both groups. The high-fit group exercised at a higher absolute workload, which resulted in a higher CO 2 production (+26%), a greater ventilatory demand (+16%) throughout the exercise, and an increased diaphragm force output (+28%) over the initial 60% of the exercise period. Thereafter, diaphragm force output declined, despite a rising minute ventilation, and it was not different between most of the high-fit and fit subjects. In summary, the high-fit subjects showed diaphragm fatigue as a result of heavy endurance exercise but were also partially protected from excessive fatigue, despite high ventilatory requirements, because their hyperventilatory response to endurance exercise was reduced, their diaphragm was utilized less in providing the total ventilatory response, and possibly their diaphragm aerobic capacity was greater.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1996.81.5.2156

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Endurance training in humans: aerobic capacity and structure of skeletal muscle.

    Hoppeler, H., Howald, H., Conley, K., Lindstedt, S. L., Claassen, H., Vock, P., & Weibel, E. R. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.2.320 · Cited by 623 · cited 1×

    “Three types of changes in response to whole body physical training have been documented to occur in the diaphragm: 1) increased oxidative enzyme activity (14, 16, 24), 2) decreased diffusion distance from capillaries to muscle due to decreased crosssectional area of type I and type IIa muscle fibers (14, 24, 25, 30),…”
    Background

Show all 1 references

Cited by

See all 93

Metadata

Authors
Babcock, M. A., Pegelow, D. F., Johnson, B. D., & Dempsey, J. A.
Venue
Journal of Applied Physiology
Published
1996-11-01
Volume
81
Issue
5
Pages
2156-2164
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2147866369
Cited by
93
References
1
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aerobic fitness effects on exercise-induced low-frequency diaphragm fatigue. https://app.cochat.ai/papers/10.1152/jappl.1996.81.5.2156
The paper
Babcock, M. A., Pegelow, D. F., Johnson, B. D., & Dempsey, J. A. (1996). Aerobic fitness effects on exercise-induced low-frequency diaphragm fatigue. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.81.5.2156

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.