Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise
The DOI matches its Crossref record.
Abstract
Proctor, David N., and Kenneth C. Beck. Delay time adjustments to minimize errors in breath-by-breath measurement ofV˙o 2 during exercise. J. Appl. Physiol. 81(6): 2495–2499, 1996.—If the delay time between gas concentration and flow signals is not adequately corrected during breath-by-breath analysis of expired gas, an error in calculation of oxygen consumption (V˙o 2) will result. To examine the frequency and delay time dependences of errors inV˙o 2 measurement, six healthy men exercised at 100, 200, and 250 W on a cycle ergometer while breath-by-breath assessment ofV˙o 2 was made simultaneously with collection of expired air. Subjects breathed first at normal rates (15–30 breaths/min) and then at 70 breaths/min. Each subject performed each level of exercise twice by using erroneous values for the delay time between gas concentration and flow signals. At normal breathing frequencies, errors inV˙o 2 measurement were ±10% over the full range of delay times used, and the errors were not tightly correlated with variations in delay times from optimum. However, at 70 breaths/min, errors approached ±30% as the variations in delay times deviated ±0.1 s from the optimal, and the errors were highly correlated with the variations in delay times. We conclude that there is greater potential for errors inV˙o 2 measurement with incorrect delay time at higher breathing frequencies. These findings suggest that the optimal delay time for breath-by-breath systems should be adjusted by using high breathing frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Decline in skeletal muscle mitochondrial function with aging in humans
Short, K. R., Bigelow, M. L., Kahl, J., Singh, R., Coenen-Schimke, J., Raghavakaimal, S., & Nair, K. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501559102 · Cited by 1,333
A PGC-1α isoform induced by resistance training regulates skeletal muscle hypertrophy
Ruas, J. L., White, J. P., Rao, R. R., Kleiner, S., Brannan, K. T., Harrison, B. C., Greene, N. P., Wu, J., Estall, J. L., Irving, B. A., et al. (2012) · Cell · doi:10.1016/j.cell.2012.10.050 · Cited by 677
Short, K. R., Vittone, J. L., Bigelow, M. L., Proctor, D. N., Rizza, R. A., Coenen-Schimke, J. M., & Nair, K. S. (2003) · Diabetes · doi:10.2337/diabetes.52.8.1888 · Cited by 631
Self-citationDHEA in elderly women and DHEA or testosterone in elderly men.
Nair, K. S., Rizza, R. A., O'Brien, P., Dhatariya, K., Short, K. R., Nehra, A., Vittone, J. L., Klee, G. G., Basu, A., Basu, R., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054629 · Cited by 566
Age and aerobic exercise training effects on whole body and muscle protein metabolism
Short, K. R., Vittone, J. L., Bigelow, M. L., Proctor, D. N., & Nair, K. S. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00366.2003 · Cited by 470
Self-citation
Metadata
- Authors
- Proctor, D. N., & Beck, K. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-12-01
- Volume
- 81
- Issue
- 6
- Pages
- 2495-2499
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2271113382
- Cited by
- 68
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise. https://app.cochat.ai/papers/10.1152/jappl.1996.81.6.2495
- The paper
- Proctor, D. N., & Beck, K. C. (1996). Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.81.6.2495
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.