CoChat

Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise

Proctor, David N., Beck, Kenneth C. · 1996 · Journal of Applied Physiology
Cited by 68

The DOI matches its Crossref record.

Abstract

Proctor, David N., and Kenneth C. Beck. Delay time adjustments to minimize errors in breath-by-breath measurement ofV˙o 2 during exercise. J. Appl. Physiol. 81(6): 2495–2499, 1996.—If the delay time between gas concentration and flow signals is not adequately corrected during breath-by-breath analysis of expired gas, an error in calculation of oxygen consumption (V˙o 2) will result. To examine the frequency and delay time dependences of errors inV˙o 2 measurement, six healthy men exercised at 100, 200, and 250 W on a cycle ergometer while breath-by-breath assessment ofV˙o 2 was made simultaneously with collection of expired air. Subjects breathed first at normal rates (15–30 breaths/min) and then at 70 breaths/min. Each subject performed each level of exercise twice by using erroneous values for the delay time between gas concentration and flow signals. At normal breathing frequencies, errors inV˙o 2 measurement were ±10% over the full range of delay times used, and the errors were not tightly correlated with variations in delay times from optimum. However, at 70 breaths/min, errors approached ±30% as the variations in delay times deviated ±0.1 s from the optimal, and the errors were highly correlated with the variations in delay times. We conclude that there is greater potential for errors inV˙o 2 measurement with incorrect delay time at higher breathing frequencies. These findings suggest that the optimal delay time for breath-by-breath systems should be adjusted by using high breathing frequencies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1996.81.6.2495

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 68

Metadata

Authors
Proctor, D. N., & Beck, K. C.
Venue
Journal of Applied Physiology
Published
1996-12-01
Volume
81
Issue
6
Pages
2495-2499
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2271113382
Cited by
68
References
0
FWCI
3.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise. https://app.cochat.ai/papers/10.1152/jappl.1996.81.6.2495
The paper
Proctor, D. N., & Beck, K. C. (1996). Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.81.6.2495

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.