Enhancement of signal quality in esophageal recordings of diaphragm EMG
The DOI matches its Crossref record.
Abstract
Sinderby, Christer A., Jennifer C. Beck, Lars H. Lindström, and Alejandro E. Grassino. Enhancement of signal quality in esophageal recordings of diaphragm EMG. J. Appl. Physiol. 82(4): 1370–1377, 1997.—The crural diaphragm electromyogram (EMGdi) is recorded from a sheet of muscle, the fiber direction of which is mostly perpendicular to an esophageal bipolar electrode. The region from which the action potentials are elicited, the electrically active region of the diaphragm (EAR di) and the center of this region (EAR di ctr) may vary during voluntary contractions in terms of their position with respect to an esophageal electrode. Depending on the bipolar electrode’s position with respect to the EAR di ctr, the EMGdi is filtered to different degrees. The objectives of the present study were to reduce these filtering effects on the EMGdi by developing an analysis algorithm referred to as the “double-subtraction technique.” The results showed that changes in the position of the EAR di ctr by ±5 mm with respect to the electrode pairs located 10 mm caudal and 10 mm cephalad provided a systematic variation in the EMG power spectrum center-frequency values by ±10%. The double-subtraction technique reduced the influence of movement of the EAR di ctr relative to the electrode array on EMG power spectrum center frequency and root mean square values, increased the signal-to-noise ratio by 2 dB, and increased the number of EMG samples that were accepted by the signal quality indexes by 50%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neural control of mechanical ventilation in respiratory failure
Sinderby, C., Navalesi, P., Beck, J., Skrobik, Y., Comtois, N., Friberg, S., Gottfried, S. B., & Lindström, L. (1999) · Nature Medicine · doi:10.1038/71012 · Cited by 636
Self-citationDrake, J. D. M., & Callaghan, J. P. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.07.003 · Cited by 399
Spahija, J., de Marchie, M., Albert, M., Bellemare, P., Delisle, S., Beck, J., & Sinderby, C. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cb0d7b · Cited by 211
Self-citationDiaphragm Activation during Exercise in Chronic Obstructive Pulmonary Disease
SINDERBY, C., SPAHIJA, J., BECK, J., KAMINSKI, D., YAN, S., COMTOIS, N., & SLIWINSKI, P. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2007033 · Cited by 201
Self-citationTitration and Implementation of Neurally Adjusted Ventilatory Assist in Critically Ill Patients
Brander, L., Leong-Poi, H., Beck, J., Brunet, F., Hutchison, S. J., Slutsky, A. S., & Sinderby, C. (2009) · Chest · doi:10.1378/chest.08-1747 · Cited by 171
Self-citation
Metadata
- Authors
- Sinderby, C. A., Beck, J. C., Lindström, L. H., & Grassino, A. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-04-01
- Volume
- 82
- Issue
- 4
- Pages
- 1370-1377
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2174779700
- Cited by
- 127
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhancement of signal quality in esophageal recordings of diaphragm EMG. https://app.cochat.ai/papers/10.1152/jappl.1997.82.4.1370
- The paper
- Sinderby, C. A., Beck, J. C., Lindström, L. H., & Grassino, A. E. (1997). Enhancement of signal quality in esophageal recordings of diaphragm EMG. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.82.4.1370
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.