The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ventilation distribution during histamine provocation
Open accessAbstract
Verbanck, S., D. Schuermans, A. Van Muylem, M. Paiva, M. Noppen, and W. Vincken. Ventilation distribution during histamine provocation. J. Appl. Physiol. 83(6): 1907–1916, 1997.—We investigated ventilation inhomogeneity during provocation with inhaled histamine in 20 asymptomatic nonsmoking subjects. We used N 2 multiple-breath washout (MBW) to derive parameters S cond and S acin as a measurement of ventilation inhomogeneity in conductive and acinar zones of the lungs, respectively. A 20% decrease of forced expiratory volume in 1 s (FEV 1) was used to distinguish responders from nonresponders. In the responder group, average FEV 1 decreased by 26%, whereas S cond increased by 390% with no significant change in S acin. In the nonresponder group, FEV 1 decreased by 11%, whereas S cond increased by 198% with no significant S acin change. Despite the absence of change in S acin during provocation, baseline S acin was significantly larger in the responder vs. the nonresponder group. The main findings of our study are that during provocation large ventilation inhomogeneities occur, that the small airways affected by the provocation process are situated proximal to the acinar zone where the diffusion front stands, and that, in addition to overall decrease in airway caliber, there is inhomogeneous narrowing of parallel airways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Consensus statement for inert gas washout measurement using multiple- and single- breath tests
Robinson, P. D., Latzin, P., Verbanck, S., Hall, G. L., Horsley, A., Gappa, M., Thamrin, C., Arets, H. G. M., Aurora, P., Fuchs, S. I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00069712 · Cited by 785
Self-citationHogg, J. C., Paré, P. D., & Hackett, T.-L. (2017) · Physiological Reviews · doi:10.1152/physrev.00025.2015 · Cited by 332
Gustafsson, P. M., Aurora, P., & Lindblad, A. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00049502 · Cited by 326
Microgravity decreases and hypergravity increases exhaled nitric oxide
Karlsson, L. L., Kerckx, Y., Gustafsson, L. E., Hemmingsson, T. E., & Linnarsson, D. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91081.2008 · Cited by 16
Metadata
- Authors
- Verbanck, S., Schuermans, D., Van Muylem, A., Paiva, M., Noppen, M., & Vincken, W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-12-01
- Volume
- 83
- Issue
- 6
- Pages
- 1907-1916
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2132023845
- Cited by
- 182
- References
- 1
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilation distribution during histamine provocation. https://app.cochat.ai/papers/10.1152/jappl.1997.83.6.1907
- The paper
- Verbanck, S., Schuermans, D., Van Muylem, A., Paiva, M., Noppen, M., & Vincken, W. (1997). Ventilation distribution during histamine provocation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.83.6.1907
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.