Reflex responses to regional venous pooling during lower body negative pressure in humans
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Halliwill, John R., Lori A. Lawler, Tamara J. Eickhoff, Michael J. Joyner, and Sharon L. Mulvagh. Reflex responses to regional venous pooling during lower body negative pressure in humans. J. Appl. Physiol. 84(2): 454–458, 1998.—Lower body negative pressure is frequently used to simulate orthostasis. Prior data suggest that venous pooling in abdominal or pelvic regions may have major hemodynamic consequences. Therefore, we developed a simple paradigm for assessing regional contributions to venous pooling during lower body negative pressure. Sixteen healthy men and women underwent graded lower body negative pressure protocols to 60 mmHg while wearing medical antishock trousers to prevent venous pooling under three randomized conditions: 1) no trouser inflation (control), 2) only the trouser legs inflated, and 3) the trouser legs and abdominopelvic region inflated. Without trouser inflation, heart rate increased 28 ± 4 beats/min, mean arterial pressure fell −3 ± 2 mmHg, and forearm vascular resistance increased 51 ± 9 units at 60 mmHg lower body negative pressure. With inflation of either the trouser legs or the trouser legs and abdominopelvic region, heart rate and mean arterial pressure did not change during lower body negative pressure. By contrast, although the forearm vasoconstrictor response to lower body negative pressure was attenuated by inflation of the trouser legs (Δforearm vascular resistance 33 ± 10 units, P < 0.05 vs. control), attenuation was greater with the inflation of the trouser legs and abdominopelvic region (Δforearm vascular resistance 16 ± 5 units, P < 0.05 vs. control and trouser legs-only inflation). Thus the hemodynamic consequences of pooling in the abdominal and pelvic regions during lower body negative pressure appear to be less than in the legs in healthy individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
JOHNSON, J. M., ROWELL, L. B., NIEDERBERGER, M., & EISMAN, M. M. (1974) · Circulation Research · doi:10.1161/01.res.34.4.515 · Cited by 340 · cited 1×
“LOWER BODY NEGATIVE PRESSURE has been used extensively to study reflex responses to venous pooling and to test orthostatic tolerance in humans (4, 12).”
MethodThe role of low pressure baroreceptors in reflex vasoconstrictor responses in man
Zoller, R. P., Mark, A. L., Abboud, F. M., Schmid, P. G., & Heistad, D. D. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107121 · Cited by 321
Cited by
Pathophysiological basis of orthostatic hypotension in autonomic failure
Smit, A. A. J., Halliwill, J. R., Low, P. A., & Wieling, W. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0001o.x · Cited by 387
“…in the upper leg (thighs, buttocks) (Ludbrook, 1966; Self et al. 1996) with less pooling in the calf and foot (Buckey et al. 1988); additionally, there is some modest pooling in the abdominal and pelvic regions (Sjostrand, 1952; Wolthuis et al. 1975; Inamura et al. 1996; Halliwill et al. 1998).”
BackgroundSelf-citationBarbieri, R., Matten, E. C., Alabi, A. A., & Brown, E. N. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00482.2003 · Cited by 307
Kimmerly, D. S., O'Leary, D. D., Menon, R. S., Gati, J. S., & Shoemaker, J. K. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.091637 · Cited by 232
“, Worcester, MA, USA) (Halliwill et al. 1998), a non-ferromagnetic height adjustable bicycle seat and a footplate were built into the chamber.”
BackgroundInfluentialLower Body Negative Pressure: Physiological Effects, Applications, and Implementation
Goswami, N., Blaber, A. P., Hinghofer-Szalkay, H., & Convertino, V. A. (2019) · Physiological Reviews · doi:10.1152/physrev.00006.2018 · Cited by 217
Masuki, S., Eisenach, J. H., Johnson, C. P., Dietz, N. M., Benrud-Larson, L. M., Schrage, W. G., Curry, T. B., Sandroni, P., Low, P. A., & Joyner, M. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00927.2006 · Cited by 91
Self-citation
Metadata
- Authors
- Halliwill, J. R., Lawler, L. A., Eickhoff, T. J., Joyner, M. J., & Mulvagh, S. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-02-01
- Volume
- 84
- Issue
- 2
- Pages
- 454-458
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1870727756
- Cited by
- 64
- References
- 2
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reflex responses to regional venous pooling during lower body negative pressure in humans. https://app.cochat.ai/papers/10.1152/jappl.1998.84.2.454
- The paper
- Halliwill, J. R., Lawler, L. A., Eickhoff, T. J., Joyner, M. J., & Mulvagh, S. L. (1998). Reflex responses to regional venous pooling during lower body negative pressure in humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1998.84.2.454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.