Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The regional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the lung volume at which the boluses are delivered. To evaluate the effect of end-inspiratory lung volume on aerosol bolus delivery, we had healthy subjects inhale radiolabeled, monodisperse aerosol (99m Tc-iron oxide, 3.5-μm mass median aerodynamic diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at lung volumes of 50, 70, and 85% of total lung capacity (TLC) end inhalation. By gamma camera analysis, we found significantly greater deposition in the left (L) vs. right (R) lungs at the 70 and 85% TLC end inhalation; ratio of deposition in L to R lung, normalized to L-to-R ratio of lung volume (mean L/R), was 1.60 ± 0.45 (SD) and 1.96 ± 0.72, respectively ( P < 0.001 for comparison to 1.0) for posterior images. However, at 50% TLC, L/R was 1.23 ± 0.37, not significantly different from 1.0. These data suggest that the L and R lungs may be expanding nonuniformly at higher lung volumes. On the other hand, subsequent retention of deposited particles at 2 and 24 h postdeposition was independent of L/R at the various lung volumes. Thus asymmetric bolus ventilation for these very shallow boluses does not lead to significant increases in peripheral alveolar deposition. These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretation of "24 Hour Lung Retention" in Studies of Mucociliary Clearance
SMALDONE, G. C., PERRY, R. J., BENNETT, W. D., MESSINA, M. S., ZWANG, J., & ILOWITE, J. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.11 · Cited by 105
Self-citation
Cited by
Aerosol Deposition in Health and Disease
Darquenne, C. (2012) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2011.0916 · Cited by 452
Möller, W., Felten, K., Sommerer, K., Scheuch, G., Meyer, G., Meyer, P., Häussinger, K., & Kreyling, W. G. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200602-301oc · Cited by 364
Self-citationParticle Transport and Deposition: Basic Physics of Particle Kinetics
Tsuda, A., Henry, F. S., & Butler, J. P. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c100085 · Cited by 264
Mucociliary and long-term particle clearance in the airways of healthy nonsmoker subjects
Möller, W., Häußinger, K., Winkler-Heil, R., Stahlhofen, W., Meyer, T., Hofmann, W., & Heyder, J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00970.2003 · Cited by 189
Self-citationLambert, A. R., O'shaughnessy, P. T., Tawhai, M. H., Hoffman, E. A., & Lin, C.-L. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2010.517578 · Cited by 175
Metadata
- Authors
- Bennett, W. D., Scheuch, G., Zeman, K. L., Brown, J. S., Kim, C., Heyder, J., & Stahlhofen, W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-01-01
- Volume
- 86
- Issue
- 1
- Pages
- 168-173
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2150000487
- Cited by
- 36
- References
- 1
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.